Well, I beg to differ. The important thing is to understand how code is designed. It seems to me the COP is irrelevant once the compressor stops but t...
There is a setting for how long after the DHW reaches the required temperature to run the pump (defaults to 5 minutes but can be read). The DHW temper...
I posted some photos of the minute by minute ASHP circuit power readings during the startup of the heating a few days ago. I doubt it is very helpful ...
One day we won’t be able to have electric motors, transformers or anything that causes a problem. We will probably have to have our own storage and on...
@transparent Using the billing information of 1.32kWh this morning when the 5kW inverter switches to battery charging at 00:45 and with an assumed b...
Yesterday the electrician completed the distribution board (consumer unit) upgrade started by having solar+batteries and Zappi EV charger installed at...
I had all my 22 rads replaced with mostly triples and a few double. I see P1 rads listed above. My Midea 12kW ASHP mostly runs at 40c leaving as the t...
@transparent, I agreed the time of GO with the installer and we then inset it 15 minutes. I know from billing that the timing is accurate. I have a...
@transparent My installer has set the system to charge during a window from 00:45 to 4:15. Everything runs from the grid in that period even if the ba...
@transparent I am UK based. The batteries are set to charge during the cheap tariff. Now spring is on the way I need to charge the batteries from the ...
@cathoderay Well done! I guess if you create HA sensors using this data you are home and dry with nice graphs. If you want the input power there are e...
I have a SolarEdge 5kW inverter but it’s limited to export 3.68kW. I also have 2x10kWh DC coupled batteries. The batteries can take everything the 6.3...
- 26 Forums
- 2,104 Topics
- 46.3 K Posts
- 94 Online
- 3,393 Members
Join Us!
Latest Posts
-
RE: Ecodan consuming 100kwh per day in new build!!!
It does indeed look like that, @skyefarmer. There is ...
By Majordennisbloodnok , 2 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist I found the switching between tariff jus...
By Toodles , 17 hours ago
-
RE: Plug and play solar. Thoughts?
Have a read of my previous posts on so-called Balcony S...
By Lucia , 20 hours ago
-
@editor @bart Hi, I can see a few problems with your in...
By Brendon Uys , 23 hours ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
"To tell you the truth, I don't know if HAL is homicida...
By Scalextrix , 1 day ago
-
RE: Location of hot water isolation valve on cylinder
@rossowheels if you isolate the water supply in it will...
By ASHP-BOBBA , 2 days ago
-
The Importance of Radiator Balancing for Efficient Heating: Introducing the Flow Regulating Valve
It’s fascinating to watch how low-temperature heating i...
By Mars , 2 days ago
-
RE: Servicing Hitachi HP in rural Somerset
I'd give GreenGenUK a call or email them: sales@greenge...
By Mars , 2 days ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 3 days ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 3 days ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 3 days ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 3 days ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 4 days ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 4 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 4 days ago