This sounds kind off odd. I run my ASHP on a room temp schedule, with a setback during the night to ensure it's off until morning (13 degrees because ...
@judith Hi, sorry, I should have been more informative. The "freeze stat" function will circulate the water traveling to and from the heat pump in the...
@ggenergy It's all in here:/p> If you are turning it off then you should have glycol in the system to protect in the event of sub-zero temps (there ...
@davidalgarve Mmm, OK that sounds odd. Is it an FTC6? The only function of the "Summer time" on/off that I can see is adding/not adding an hour to the...
@davidalgarve Hi, I"m not convinced about your observation as I originally had "Summer time" set to "Off" and still had to manually change the time. I...
You would be wrong! In prohibit mode the Frost Protection mode does not activate - so at least Ecodan support were correct. As it stands this function...
@davidalgarve Hi, it's a PUZ-WM85VAA with a pre-plumbed cylinder type thing. They are fairly common.
Hi @majordennisbloodnok . It's probably best to leave how I'm operating the ASHP to one side as it's orthogonal to the topic, which is the limited me...
@gary I don't use Tado and the Mitsubishi room stat is in the hall and will reach 14 soon enough.
OK, I've turned the heating off and put Frost Protection on with min 14 and max 16. I'll post the results of the experiment in the evening!
- 26 Forums
- 2,104 Topics
- 46.3 K Posts
- 142 Online
- 3,393 Members
Join Us!
Latest Posts
-
RE: Location of hot water isolation valve on cylinder
@transparent Thank you so much and very helpful. Earlie...
By rossowheels , 12 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@toodles Indeed. On a tariff such as IOF where import a...
By Old_Scientist , 13 hours ago
-
RE: Ecodan consuming 100kwh per day in new build!!!
It does indeed look like that, @skyefarmer. There is ...
By Majordennisbloodnok , 19 hours ago
-
RE: Plug and play solar. Thoughts?
Have a read of my previous posts on so-called Balcony S...
By Lucia , 2 days ago
-
@editor @bart Hi, I can see a few problems with your in...
By Brendon Uys , 2 days ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
"To tell you the truth, I don't know if HAL is homicida...
By Scalextrix , 2 days ago
-
The Importance of Radiator Balancing for Efficient Heating: Introducing the Flow Regulating Valve
It’s fascinating to watch how low-temperature heating i...
By Mars , 3 days ago
-
RE: Servicing Hitachi HP in rural Somerset
I'd give GreenGenUK a call or email them: sales@greenge...
By Mars , 3 days ago
-
RE: Heating coming on when not required
I played with a max heating temp but there is a world o...
By JamesPa , 3 days ago
-
RE: Pressure drop Primary circuit
I've always regarded topping up heating systems as my j...
By JamesPa , 3 days ago
-
RE: Heat pump solutions and/or installer recommendations for France
I’d travel to France for work if you were struggling wi...
By Damon Blakemore , 4 days ago
-
RE: 5 Star Service from Havenwise
That's always a danger with any new good idea, @morgan....
By Majordennisbloodnok , 4 days ago
-
Have your say in the Renewable Heating Hub Awards
It’s time to celebrate the best (and call out the worst...
By Mars , 4 days ago
-
-
RE: Mitsubishi cycling while on chilled water output
@iaack yes there's no denying that cold air sinks! I s...
By downfield , 5 days ago
-
RE: Weather compensated secondary circuits with Biomass
@andycoo that flooring sounds ideal. Extra volume is ...
By Sune , 5 days ago