Some manufacturers do publish operating data performed during standard test conditions. That is the source of data behind the Modeling Tools I have cr...
Don't worry, the neighbours will complain about the noise and then the heat pump will have to be moved or removed. But having been installed it will h...
The temperature sensor will be inside the controller, unless you have installed a remote unit, so will be of no use for room temperature control. Yo...
Where is the controller located?
It would appear that your heat pump is cycling. Is your heat set for a fixed Leaving Water Temperature (LWT), in Weather Compensation (WC) mode, or ...
@cathoderay Excellent data once more. The fact that the OAT reading appears to increase by approximately 5C during the setback period, would make ...
The reason that I mentioned the cycling was because of the fact that it makes doing an accurate comparison between theoretical and actual that more di...
Could you explain the reason for wanting the heat pumps to run in tandem? I would have thought that if the actual heating demand, is not greater than ...
@cathoderay The Modbus registers are two byte 16 bit long. When displayed in binary the left-hand end is normally denoted to be the Most Significant...
@jamespa Sorry James, I forgot to fully answer your query. The WC Modeling Tool infers that Energy Supply will be a product of LWT and the capacit...
@jamespa Yes, the raw data was kindly supplied by CathodeRay, the accuracy of which I am not questioning. My objective is to try to avoid the comp...
AA mode is designed to keep the IAT constant, so to the controller even 1C setpoint change is a large deviation between desired and actual. This is th...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 161 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@kevh it's worth remembering that many lsvs only actual...
By JamesPa , 16 hours ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 22 hours ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 1 day ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 1 day ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 1 day ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 1 day ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 2 days ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 2 days ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 2 days ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 2 days ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 2 days ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 2 days ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 2 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 3 days ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 3 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 4 days ago