Reply
RE: Daikin Altherma 3M in Buckinghamshire

Hi Bridget, It is difficult trying to assess precisely what is happening within your system, when one is not actually present to witness it oneself....

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

@jeff Help from MCS is reliant upon the customer knowing that there is a problem. In cases where the heating system works in a fashion, but is inef...

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

Hi Mars, You have had discussions with the staff at MCS. Whilst they set the standards installation, do they have any responsibility for enforcement...

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

Hi Bridget, I have had a further thought. What is the diameter of the pipework on your system? If you have a change in pipe diameter, then the veloc...

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

Hi Everyone, The text below is an extract from a Daikin installer manual. I wonder how many customers actually received this level of service? 10 ...

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

@bridgetjohn Hi Bridget, The following is an extract from the manual. 5.2.5 To insulate the water pipingThe piping in the complete water circui...

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

@bridgetjohn Hi Bridget, So that we can try to help you cure the noise problem, could you provide details of the conditions under which the noise...

4 years ago
Reply
RE: ASHP Install from hell part 1 - the schematic - EXPERTS PLEASE VIEW

I am pleased to see that at least one disreputable installer is being taken to task. 😮

4 years ago
Reply
RE: Electronic smart TRVs and our ASHP

Hi, When you have the time I would suggest that you read through some of the trends concerning heat pump efficiency, where I have explained in detai...

4 years ago
Reply
RE: Daikin Altherma 3M in Buckinghamshire

Hi Bridget, The Booster Heater is actually the Immersion Heater in your hot water cylinder. Obviously it would be preferable from an efficiency poin...

4 years ago
Reply
RE: Balancing radiators with heatpumps

That should work if your hand is accurately calibrated. 😎

4 years ago
Reply
RE: Electronic smart TRVs and our ASHP

If you want a real solution to your problem, you should get rid of the TRV's and thermostats and set your heat pump to operate using weather compensat...

4 years ago