Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 12, 2025
@HughF - The cylinder is a pre-plumbed Ecodan Unit and have had a look at the catalogue and this is how it is factory set.?
@HughF, sorry I didn't understand what you mean about plate loading?
Derek.......sorry for the delay in responding, I have had to wait until i was fit enough to get in the loft! Regarding pump speeds........I am now r...
Just managed to get in the loft and look at this. I do have both expansion tanks but I also have the low loss header which is part of the packaged c...
@sunandair Not sure if I have a buffer or low loss header tank, I know up there in the loft there are two expansion type vessels of similar size?.....
@derek-m Derek, sorry for late reply I dropped the pump speed to 1 running at 10 l/min and Delta T increased to about 2.5 / 3 c on Melcloud, I ha...
@kev-m Thanks Kev.....A simplistic approach is probably always the sensible one..........as you say its obvious to me now 🙄 that Melcloud is the is...
@sunandair Hope you get sorted soon........hang in there!!
@sunandair .............thanks... what COP figures do you achieve and are you using Auto Adapt (Room Mode) or WC?
@sunandair Many thanks my unit is the 85 with range between 10.8 and 24 not sure what determines the optimum but as just posted have dropped pump ...
@mjr, @derek-m & @Kev-m Thanks for all your input. I have looked at the Service Menu and noted that the Pump speed is 5 and flow rate 19 l/min...
@derek-m Hi Derek It's been close to freezing all day and the Curve is still maintaining the whole house comfortably, it's now down to 39C at -5C...
- 27 Forums
- 2,758 Topics
- 64.9 K Posts
- 1,455 Online
- 7,162 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Where heat loss surveys seem to go against practical reality
I am amazed that there is not something out there to me...
By JamesPa , 3 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
@bobflux The hydraulic simulator is very interesting...
By Rob of York , 9 hours ago
-
RE: 7kW EV Charger Options Advice
Thanks. Yes, we have patchy 4G. The only option we had ...
By Rusty , 14 hours ago
-
-
RE: Being screwed over by Volkswagen Audi Group
Thanks, @batpred. That integration is the one I have in...
By Majordennisbloodnok , 1 day ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
@batpred I suspect it will be more this year. I had 9 ...
By AndrewJ , 1 day ago
-
RE: Surface mount or bury primaries for heat pump installation?
@jamespa It's rusting 🙂
By tomasmcguinness , 1 day ago
-
RE: Glass lined Cylinder for private water supply
Thank you, once again, for your replies. Yes...
By ian33a , 1 day ago
-
It’s been out a few days and Amazon has already attache...
By Mars , 1 day ago
-
RE: Missing flow temperature in Heat Geek proposal
Yes, and this is another point I agree. We did find a f...
By Batpred , 2 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
A very good point. In effect, the DHW pipework is an em...
By cathodeRay , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
@tim441 Here are those same three month periods for 202...
By Toodles , 4 days ago
-
RE: Adding additional Solar Panels to a DC coupled battery system
@transparent thank you for your reply above. As alway...
By Old_Scientist , 5 days ago
-
RE: Adventures in heat loss calculations
@rob-of-york — thanks for posting this, all very useful...
By cathodeRay , 6 days ago