Activity
 
Notifications
Clear all
cathodeRay
cathodeRay
@cathoderay
Moderator
Famed Member
Joined: Feb 28, 2022
Last seen: Aug 8, 2025
Topics: 17 / Replies: 2075
Reply
RE: Connecting Home Assistant to a Midea Heat Pump

Another thought, in reality a restatement of @derek-m's thinking, perhaps my implied assumption that one minute's energy in is directly responsible fo...

2 years ago
Reply
RE: Connecting Home Assistant to a Midea Heat Pump

In the yellow highlighted section, sort of. What happens is this. The space heating is on 24 hours a day, and uses weather comp to regulate heat outpu...

2 years ago
Reply
RE: Connecting Home Assistant to a Midea Heat Pump

In the on_off columns, it is being used as a binary on/off value, but being a number it has the useful side effect it can be used to zero a calculatio...

2 years ago
Reply
RE: Connecting Home Assistant to a Midea Heat Pump

@iaack - thanks. The 11.6, which is definitely for the hour not minute, is definitely an artefact, caused by the erroneously high energy out figures f...

2 years ago
Reply
RE: Connecting Home Assistant to a Midea Heat Pump

@derek-m or indeed anyone - I have almost got the python code to do everything I want, including allocating energy in and out to space heating or DHW ...

2 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

@william1066 - it goes without saying (at least I hoped it did) that what I write about HA is based on my observations experience and opinions. ...

2 years ago
Reply
RE: A Beginner's Guide to ASHP Monitoring

@majordennisbloodnok - thanks as ever for your welcome thought and comments. I think this thread, and the 'journey' it documents, is a sort of necessa...

2 years ago
Reply
RE: Flawed ground source heat pump system: low pressure faults and high running costs

@editor - very glad to hear about your background, it puts you in a good place to deal with this. Despite being legalistic in my earlier post, I also ...

2 years ago
Reply
RE: Flawed ground source heat pump system: low pressure faults and high running costs

@kev-m - I've done a fair amount of writing in my time, and some of it has been close to the bone, meaning I have to know about libel, and yes it is a...

2 years ago
Reply
RE: Samsung ASHP scheduling help

Sorry, should have been clearer. Here's my setup in a rather unelegant image, but I hope at least clearer: It's similar to the Samsung set up,...

2 years ago
Reply
RE: Samsung ASHP scheduling help

That got me thinking. I think it is more accurate to say the heat pump (ie the PCB in the outside box) is the true slave, and the wired controller is ...

2 years ago
Reply
RE: Samsung ASHP scheduling help

I'm pretty sure that is the standard setup, and it is the same set up for me, in my case mini PC running the python code is the master, Midea wired co...

2 years ago