Air source should use 3-4x less electricity than oil filled or electric radiators. but it has to be set up correctly If that 44c on your disp...
@winnie-wicket Can you post a pic of the main controller, which will probably be near your water tank? Take a pic of any screens you can access ...
Quick Q I’ve tweaked our WC curve. It’s been running at between 25-39c this week. today for example it’s 11c outside and running at 26c flow. 5c ...
Just for the long pipe run we had this. You can get preinsulated pipe which you bury and therefore it has less heat loss (as underground is warmer tha...
I set the mode to normal (which favours economy over fast warm up/comfort). I also changed the interval from 10mins to 60mins my guess on that i...
Do you have 3 phase electric? Just because the 3ph Ecodan is approved for Connect and Notify.
It’s not bending the rules though if it’s less than 60amp. You simply don’t need to inform them prior Mines a 14kw and we didn’t pre notify them...
@waylander that does make sense as they will plan for the worst and look at the peak usage. but if you can avoid informing them prior it’s not an i...
Do you need their permission? I think you can notify them afterwards 2. Connect & notify This scenario applies to properties with new M...
@batalto Basically what I listed in the first post.
@hjd yes its fairly straightforward The receiver clips onto the control board, then you need to pair the receiver with the controller. The...
Been running heating for a couple of days on new simpler setup COP has been between 4 and 5. Last year was 3.3 at same time of year. Admitte...
- 21 Forums
- 1,967 Topics
- 42.7 K Posts
- 66 Online
- 2,280 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Is it KISS or constant – weather compensation vs. set flow temperature?
Keep it out in the open! Others will want to have a loo...
By cathodeRay , 28 seconds ago
-
RE: Battery storage to run Heat Pump.
@jamespa Im interested in that comment. I would l...
By Lucia , 2 minutes ago
-
RE: Setback savings - fact or fiction?
@jamespa - thank you for your ongoing heroic attempts t...
By cathodeRay , 18 minutes ago
-
RE: Have Consumers Been Lied to About the Efficiency of Heat Pumps Made in China?
Whats the real world impact of the COP data being sligh...
By Tom , 43 minutes ago
-
RE: Towel rails. An unexpected final hurdle
@davesoa No, unfortunately. I had to pay the VAT becaus...
By Lucia , 1 hour ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@editor I have been persuaded by the argument that you ...
By SUNandAIR , 2 hours ago
-
RE: SolarPV tables / online calculator
@majordennisbloodnok what degradation per year is typic...
By MichelleC , 2 hours ago
-
RE: Who's your electricity provider and what's your tariff?
I watched it. I found it an interesting discussion but...
By JamesPa , 3 hours ago
-
RE: Daikin Heat Pump Cycling Frequency?
I think your current method of logging F-gas pipe tempe...
By Mars , 13 hours ago
-
RE: Baxi Air Source Heat Pump tips and tricks please
@cathoderay thank you, I will.
By Cathyem1 , 16 hours ago
-
Very sensible. Get the 'second round' quotes in, hopef...
By JamesPa , 16 hours ago
-
RE: Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
Sorry, yes, 2105. OOPS! If I recall the unit circulates...
By AllyFish , 18 hours ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
No pressure or obligation, this discussion has moved on...
By JamesPa , 18 hours ago
-
RE: Split system and pipe lengths for air source heat pump installation
@johnmo got it. Thanks.
By nickmorgan , 20 hours ago
-
RE: Ecodan ASHP - How to optimise my set up?
Thanks everyone for posting this, so much useful info t...
By Bamnio , 1 day ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
I have the same pump and if I am operating it correctly...
By Broadsman , 1 day ago
-
RE: What is the best strategy for operating a very oversized heat pump?
This whole discussion highlights just how much of a mes...
By Mars , 2 days ago
-
RE: NIBE F2040 12 kW heat pump and 100 liter buffer tank
@cheshirejohn thanks for the update and for sharing. I’...
By Mars , 2 days ago
-
@robs useful thread! Thanks for sharing - Octopus are c...
By big_si , 2 days ago
Latest Topics
-
Daikin Heat Pump Cycling Frequency?
By Ubert767 15 hours ago
-
Battery storage to run Heat Pump.
By Broadsman 1 day ago
-
Heat Pump Sizing & Installation Costs
By Mars 2 days ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
By Mars 2 days ago
-
SolarPV tables / online calculator
By MichelleC 2 days ago
-
Samsung Gen 7 R290 12kW is not behaving how I expected
By Joshua 3 days ago