Air source should use 3-4x less electricity than oil filled or electric radiators. but it has to be set up correctly If that 44c on your disp...
@winnie-wicket Can you post a pic of the main controller, which will probably be near your water tank? Take a pic of any screens you can access ...
Quick Q I’ve tweaked our WC curve. It’s been running at between 25-39c this week. today for example it’s 11c outside and running at 26c flow. 5c ...
Just for the long pipe run we had this. You can get preinsulated pipe which you bury and therefore it has less heat loss (as underground is warmer tha...
I set the mode to normal (which favours economy over fast warm up/comfort). I also changed the interval from 10mins to 60mins my guess on that i...
Do you have 3 phase electric? Just because the 3ph Ecodan is approved for Connect and Notify.
It’s not bending the rules though if it’s less than 60amp. You simply don’t need to inform them prior Mines a 14kw and we didn’t pre notify them...
@waylander that does make sense as they will plan for the worst and look at the peak usage. but if you can avoid informing them prior it’s not an i...
Do you need their permission? I think you can notify them afterwards 2. Connect & notify This scenario applies to properties with new M...
@batalto Basically what I listed in the first post.
@hjd yes its fairly straightforward The receiver clips onto the control board, then you need to pair the receiver with the controller. The...
Been running heating for a couple of days on new simpler setup COP has been between 4 and 5. Last year was 3.3 at same time of year. Admitte...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 88 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@kevh it's worth remembering that many lsvs only actual...
By JamesPa , 10 hours ago
-
@majordennisbloodnok Education, Education, Education…
By Toodles , 12 hours ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 16 hours ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 19 hours ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 1 day ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 1 day ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 1 day ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 1 day ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 1 day ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 1 day ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 1 day ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 2 days ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 2 days ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 2 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 2 days ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 2 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 3 days ago