@jamespa @bontwoodyHeat loss calculations found and attached. Although of course the room areas are incorrect 🙄From this do I assume the 8276...
@jamespa cannot find loss calculation. When they get in touch I'll query it.
@majordennisbloodnok Absolutely! You only have to look at the plan to see the room measurements don't make any sense.The chap who gave me the documen...
It's INSANE how wrong they have the sizing (and even shape) of my house on the schematics 😲 No sizing for patio doors Missing window in ba...
OMG, the attached schematics (even with incorrect room sizes) says it should be an 8kw ASHP, not 12!!
@bontwoody I can't see anything in the documentation that says it's a heat loss calculation but there's 20 odd bits of paper so I'll keep looking.Atta...
Hi to all those who have generously replied to this thread. I've now had another discovery.The 3rd bedroom is always too cold. I measured the room s...
@bontwoody It's not inbetween the glass but on the glass itself. I'll do a bit more investigating! I'm still getting used to the house, which has be...
@bontwoody There's definitely something amiss with the picture window. I get lots of condensation on there in a morning and zero condensation on any ...
@jamespa I'm so lucky - I have views of the nearby Pennines from the picture window at the front (if you ignore the other bungalows annoyingly built i...
@johnr Hadn't thought about secondary glazing - definitely worth pondering, thank you!
@johnr An extra rad was installed in the lounge when the ASHP system was put in, so it has two (room measures 14ft x 20ft).I had a lightbulb moment re...
- 26 Forums
- 2,171 Topics
- 47.8 K Posts
- 36 Online
- 5,744 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Powerwall 3 or Myenergi or something else?
Having had a chance to test this now, I can confirm tha...
By Old_Scientist , 19 minutes ago
-
Mitsu PAR-WT60R Wireless Controller - options
I hope I have satisfactorily installed the above wirele...
By DavidAlgarve , 22 minutes ago
-
WC curve best discovered by experiment anyway as any lo...
By JamesPa , 5 hours ago
-
RE: Big Changes Coming to Our Heat Pump System
@editor your engineer's attitude is truly horrifying. ...
By GrahamF , 22 hours ago
-
RE: How to choose Towel Rails for an ASHP
@rob-nezard yes absolutely. Here is the link and a pho...
By GrahamF , 1 day ago
-
@mixergy Thanks for the update, I would appreciate some...
By bontwoody , 1 day ago
-
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?
Unfortunately I'm not that well connected 😂 ...
By Scalextrix , 1 day ago
-
RE: A Customer's Lessons Learnt from a Heat Pump Installation in a Large House
It is interesting to see what our new Grant Aerona 290 ...
By GrahamF , 1 day ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
I've never physically seen it, but I seem to recall som...
By cathodeRay , 1 day ago
-
@jamespa Ours is a Daikin EDLA03 8 kW and the Delta T =...
By Toodles , 1 day ago
-
RE: Midea ASHP – how to set weather compensation
I noticed that too and thought the same thing, but then...
By cathodeRay , 2 days ago
-
RE: Ya can’t win! It is S*d’s Law!
@old_scientist If IOF is still running next late spring...
By Toodles , 2 days ago
-
RE: Electricity price predictions
Those of you on Agile will do well tomorrow; there are ...
By Toodles , 2 days ago
-
RE: Who’s Caved and Switched the Heating On Already?
We've been running our Ecodan system, installed in June...
By Sheriff Fatman , 2 days ago
-
Ok. Two schools of thought. The first is to run the ...
By JamesPa , 3 days ago
-
@drei Willing as I am to help, I don't think I'm yet ...
By JamesPa , 3 days ago
-
Selling 5 year old ASHP & Gas Combi Boiler - £590
Selling a 5-year-old Daikin Altherma Hybrid Air Source ...
By Paul G , 3 days ago
-
RE: Help me keep the faith with my air source heat pump installation
Er true, it should have read l/hr!
By JamesPa , 3 days ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Much of that is true in principle, but its not likely t...
By JamesPa , 5 days ago