@crimson good morning. Lots of people here want this one fixed for you! What's the approximate length of buried pipework on the primary circuit under ...
Hi @crimson, sure. The formula is the sensible heat equation, to work out how much heat energy in kJ/s is being added. 9 is your flow rate as indica...
@crimson great stuff. The delta T between flow and return is high, especially when your ASHP is on low load, 1300W power consumption, that's about 1/3...
@Crimson, I hesitate to state it, but it seems like your plumbers are clueless. You need a fresh pair of eyes on the job as there's something seriousl...
Finally Grant is waking up and smelling the coffee and, when they offer their 'smart controller' option pack (which monitors primary flow rate), they ...
Hi @crimson, probably time to bite the bullet and get the system checked over by Grant. The installation manual from Grant has suggested circuits for ...
Some progress on the hot water. Reducing the flow on the secondary side to balance with the deficient flow on the primary side is a sticking plaster. ...
@crimson small steps towards a resolution. The flow rate is a biggie, that needs fixing. That will be throwing a spanner in the works in the LLH if th...
Hi @crimson, the flow rate is constant for Grant systems, as they have a fixed speed pump in the ASHP. If your primary flow rate is 9l/min, and the fl...
@crimson - is that flow rate photo taken with the ASHP running? It's showing a flow rate about 9 litres/minute. If so, that's way below Grant's minimu...
Most Grant Aerona ASHPs work on a DT of 5degC, they will push up to 8degC, but seem happiest with a low DT. If you are in the habit of turning the hea...
Psychrometric trickery this week. It's cold outside, but low relative humidity. The sort of 'dry cold weather' that Scandinavia routinely gets, and wh...
- 21 Forums
- 1,972 Topics
- 42.9 K Posts
- 58 Online
- 2,303 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Heat Pump Sizing & Installation Costs
100m2 5kw £11000-£7500=£3500 pick 3 radiators
By Adrian , 3 minutes ago
-
RE: Setback savings - fact or fiction?
I think the theory should be that you save what the dif...
By Adrian , 7 minutes ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
@adrian I think that the company might argue that if th...
By Toodles , 11 minutes ago
-
RE: Grant ASHP not reaching target temperatures
@hillswick if you engage more radiators then it will ta...
By Gary , 14 minutes ago
-
Based on the numbers I think its likely its oversized. ...
By JamesPa , 1 hour ago
-
RE: Transforming a Derbyshire Property into an Energy-Efficient Haven
@carpenterstation That's helpful, thank you. The de...
By Morgan , 2 hours ago
-
RE: What is the best strategy for operating a very oversized heat pump?
@jamespa Homely does address many of these issues, but ...
By Arundalep , 5 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
There is absolutely nothing wrong with buffer tanks in ...
By JamesPa , 10 hours ago
-
RE: Replacing knackered oil boiler with ASHP - Perthshire
@abernyte thanks tbh I was more thinking about bolsteri...
By DowallyDrifter , 10 hours ago
-
RE: Battery storage to run Heat Pump.
@jeff The government are quite happy for the network ...
By Lucia , 22 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist The OE guidelines mention that their con...
By Toodles , 1 day ago
-
RE: Adjusting 6kW Daikin's Weather Compensation Curve
@jamespa I'm grateful for your advice.
By Ubert767 , 1 day ago
-
@heatgeek thanks! I contacted them too.
By Eliuccio , 1 day ago
-
RE: Is it KISS or constant – weather compensation vs. set flow temperature?
Thanks. I've seen the video several times at the beginn...
By cliffhanger , 1 day ago
-
RE: Say hello and introduce yourself
@carrownisky where are you based? Would you like me con...
By Mars , 1 day ago
-
RE: Baxi Air Source Heat Pump tips and tricks please
@transparent Good morning, the installer sorted our m...
By Cathyem1 , 1 day ago
-
@roodo welcome to the forums and I’m really sorry to he...
By Mars , 1 day ago
-
RE: Thinking of ripping our my IVT Greenline HT Plus C model and replacing with a gas boiler.
Don’t rip out a IVT! Amazing heat pump! Unless your com...
By greenlight , 1 day ago
-
RE: Sunamp Thermino Heat Battery
Wow, I knew they were pricey, but didn’t expect it to b...
By Mars , 2 days ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
@matthew_w good luck with the quotation and proposal pr...
By Mars , 2 days ago
Latest Topics
-
Should I make my radiators smaller?
By Scalextrix 2 days ago
-
Daikin Heat Pump Cycling Frequency?
By Ubert767 3 days ago
-
Battery storage to run Heat Pump.
By Broadsman 3 days ago