If the heat pump has been properly commissioned, then it should be maintaining the 'set temperature' as defined in the design, which was based on the ...
Unfortunately @burtis James is right. MCS is the Government's preferred vehicle to deliver the domestic initiatives they wish to promote (solar pane...
Just a word about the Retail Energy Code (RECC) organisation @editor When first formed it was tasked with pulling together all official documents a...
It is indeed a lot of water @johnmo But my starting point is a 280-litre thermal store! Whenever I've needed to release water to 'work' on the h...
Great.... This is the sort of related information we need @toucan Don't worry about grammar, or trying to organise the issues...... just fire them a...
The new NESO website is now live. A lot of pages have simply been moved across from the old National Grid ESO website. The Electricity Ten Year St...
Agreed @johnmo - a combined product can tackle multiple issues simultaneously. I'm just providing the link to that Flomasta product from Screwfix. ...
OK @toucan That's helpful. But you won't get any corrosion prevention from adding glycol.To achieve that you require an Inhibitor which prevents ox...
Feel free to comment @katler Very few consumers know anything about how our UK energy supplies operate.Would it help if we understood it better? I...
Keep receipts, and a diary of what you do. That will be required if you find yourself going down the route of Arbitration or Small Claims Court. T...
I don't like using glycol unless absolutely necessary. The specific heat capacity of water is 4200 J/kgΒ°C, whereas Glycol is only 2433 J/kgΒ°C.Adding...
- 26 Forums
- 2,114 Topics
- 46.4 K Posts
- 35 Online
- 3,410 Members
Join Us!
Latest Posts
-
@jamespa Thanks. I did not instruct them not to insul...
By Eliuccio , 1 hour ago
-
RE: No-code, plug-and-play monitoring for your heat pump
To update an ESP device using ESPHome in Home Assistant...
By Grantmethestrength , 1 hour ago
-
RE: Compressor and Evaporator Stratification
@trebor12345 I must admit I noticed that about Hitachi ...
By ASHP-BOBBA , 3 hours ago
-
RE: Is this just haze or something more?
I am not a scientist nor a meteorologist and I know the...
By Toodles , 2 days ago
-
RE: Benefits of an extra horizontal loop for GSHP
It will improve performance, but by how much depends on...
By Brendon Uys , 2 days ago
-
RE: The good, the bad and the not that great β my heat pump installation
Said I would pop back with a update. Only Mr Jesus h...
By Burtis , 3 days ago
-
RE: Buffers, hot water and cooling
Thats presumably heat pump DT, what about radiator DT a...
By JamesPa , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
@chandykris Exactly the same here. We now have 13.5kWh ...
By Old_Scientist , 3 days ago
-
RE: Wood burner with ASHP - direct air?
This depends on the size of your wood burner and size/t...
By Lucia , 4 days ago
-
RE: Difficult positioning of air source heat pump
@rikiarn It's a not a buffer it's a volumiser which is ...
By Lucia , 4 days ago
-
RE: Is your heat pump insured?
To make things clear, lots of insurance companies cover...
By Lucia , 4 days ago
-
RE: Boxt Heat Pump Installation Experience
@adrian any updates since installation? How is it perfo...
By Ashfp , 4 days ago
-
RE: Say hello and introduce yourself
Hi @seatonian - Yes, I know Seaton, and I have the Nat...
By Transparent , 5 days ago
-
@seatonian got your email. Will connect you with a reco...
By Mars , 6 days ago
-
@downfield and @toddles, this isnβt in the settings cur...
By Mars , 1 week ago
-
RE: Homely launched for Grant Aerona ASHP control
I haven't bought the Aerona Smart Controller (Β£700!) bu...
By Prunus , 1 week ago
-
RE: Antifreeze top up for my heat pump - is this a rip off?
For the record, Grant supply ethylene glycol for their ...
By Prunus , 1 week ago
-
RE: Compressor attempts start but fails - Nibe Fighter 2005 8kW
@skyefarmer amazing. Well done!
By Mars , 1 week ago
-
RE: Air source heat pump roll call β what heat pump brand and model do you have?
Ebac 5kw - Monobloc R32. Developed and made in UK - Mit...
By marcinwloch69@gmail.com , 1 week ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Just another thought - it might be worth thinking about...
By JamesPa , 1 week ago