Reply
RE: New Fogstar 15.5kWh upright solution

Please clarify @bash Did you top-balance the cells before installing them in the Seplos enclosure,or were you relying on the inbuilt BMS to handle t...

3 weeks ago
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

If they do refuse,then they probably didn't intend it to be refuse in the first place 🤗

3 weeks ago
Reply
RE: Maximising Home Automation: Integrating Octopus Energy & More

Haven't reached the stage where one of you is going to post a generic diagram of the 7-level OSI model? There will be others considering HA in futur...

3 weeks ago
Forum
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

Yes, a gas boiler would be a legitimate reason for such air vents. I don't know what their external face looks like, but I would recommend a tempora...

3 weeks ago
Reply
Reply
RE: Maximising Home Automation: Integrating Octopus Energy & More

Apologies, I'd missed that earlier post. James is correct. Consumers cannot directly contact the Communications Hub box of a Smart Meter. The Comm...

3 weeks ago
Forum
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

Is your reference to 6.7kW based on the initial post in this topic? The OP stated in that post "The heat loss calculation then provided by the insta...

3 weeks ago
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

That's an interesting use of the phrase 'site-specific conditions'. I've met it being used elsewhere when a contractor wishes to simultaneously clai...

3 weeks ago
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

@mairia - if you want to try following the discussion about the buffer tank, there are two previous topics with diagrams to help. See this one about...

3 weeks ago
Reply
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?

The buffer tank is beneath the DHW tank. The DHW section has a brass drain-valve facing us. The blue-handled lever valve is on a pipe which seems ...

3 weeks ago
Reply
RE: RDSAP10 effect on existing heat pump EPC rating?

The house is T-shaped @toodles. The SW side has another part of the roof at right-angles to what's visible in the photo. I would've put PV on th...

4 weeks ago