Last seen: Feb 18, 2025
@lakey thanks. i don’t think my Mrs will ever sign off on taking everything out of the downstairs to do it….kitchen out, toilet out, more new fl...
the issue with this is…on the earlier drawings, if all those drains and gulley run into that one manhole, which is now under my concrete floor and als...
hi, again apologies for the delayed reply 1. Good guesses, I expect you’re quite accurate, we are ready to try and make it more inhabited hence ...
I’ll reply to your numbered points, I appreciate it’s been a long time but I’ve been juggling a lot recently 1. I think I queried this with BC b...
what’s the floor area for that quote, out of interest? I was recently quoted about £6k for 100m2 (whole ground floor) or £3750ish for 57m2 (just...
@transparent yeah…that…see pic ’gulley’ would be the kitchen waste soil stack is in the right place the rain pipe isn’t there, you can just ...
@transparent I just rechecked the quote (jk floor heating), it is 125mm spacing but in discussion they suggested the conservatory may benefit from 100...
I’ve tried to attach some images here from the IR survey I had done…you can see the dot and dab walls but I don’t get why they don’t get damp/soak wat...
@jamespa I measured the back wall external today - about 5.1m. Internally the same wall was something like 4.76m-4.82m. All a bit rough, I know, but i...
@transparent the date was a concern, I thought it might be around the time the rules tightened up a bit we had all the flooring and skirts replaced ...
@transparent I don’t think I’ve seen something so complicated on a residential roof before, but I did suspect the shallow pitch could be why! I’m ke...
@judith thanks for this, I’ve requested a local installer to contact me. We had a quote in 2022 to externally insulate just the annex and it was £5400...
- 26 Forums
- 2,289 Topics
- 51.4 K Posts
- 261 Online
- 5,949 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: DHW heat loss through pumps.
@marzipan71 Morning, it looks as though it's a very muc...
By ngillam , 18 minutes ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira
A very interesting episode, and it was good to hear a c...
By Sheriff Fatman , 8 hours ago
-
I signed up to Havenwise control on the day after the h...
By Sheriff Fatman , 9 hours ago
-
So I can now confirm that no MCS qualified person ever ...
By Batpred , 9 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Very sound reasons imho. My current feel, albeit based...
By JamesPa , 11 hours ago
-
RE: Electricity price predictions
In general, in order for the market to work and drive p...
By Batpred , 11 hours ago
-
That's not always the case.Let's see what they say once...
By Transparent , 13 hours ago
-
Hello All Our solar system consisting of 2 x 6Kw inve...
By AlanB , 14 hours ago
-
RE: BUS grant voucher expires before install date
@bornagain That is what our installer is pr...
By Bash , 14 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
I'm not so sure. New gas boiler £10...
By Bash , 17 hours ago
-
RE: Renewables & Heat Pumps in the News
I thought an aircon doubling as a heat pump could do ou...
By Batpred , 18 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Just wanted to share some info for anyone facing challe...
By Batpred , 20 hours ago
-
Daikin Altherma HT Temperature Sensor Question - Caution: Mentions AI...
Hi All - first post for a while, hope you are all well,...
By Marzipan71 , 20 hours ago
-
RE: Do Heat Pumps need to start up at Full Power?
@steelbadger We have an LLH with secondary pump; the se...
By Toodles , 23 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
And the saga continues… So today a Senior Grant Engin...
By Crimson , 2 days ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@jamespa Yes, the OAT sensor is situated on the back pa...
By Toodles , 2 days ago
-
RE: Ecodan ASHP Low COP and Unstable Compressor Frequency
Just to clarify, returning water from UFH is colder tha...
By lukewarmbath , 2 days ago
-
RE: 10kw heat pump run in 24*7 data?
A different heat pump (Midea 14kW) but a stark reminder...
By cathodeRay , 2 days ago