Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jul 1, 2026
I am assuming you are aware of the FTC(6, I think) pump speed settings that allow you to set a different circulating pump speed for space heating to t...
[quote][/quote] Having read up on the matter since, the Ecodans do not do this - they run at one speed, be that which is set internally on the pump ...
Assume so too. I think my pipes are at 150mm centres, which I understand is common for screeded underfloor - but I watched the HG video and (mainly!...
Feels like this was way out after some of the replies, however are there any rules of thumb on such matters - for example, given UFH in an area of Xm2...
How do people find switching from DHW to space heating in respect of the flow and return temps? For example, going from a 52C flow (for 47C DHW temp)...
I asked the question to gain more understanding in the context of the flow/return temps rather than that being what I wanted to/was planning to achiev...
I lowered my flow rate to c. 11L/m for the Ecodan and the heat/power output went down to c. 3.8kW :-/ The deltaT remained around 5 so I assume Ecodan...
This may seem like a daft question but can I please check - one should always aim for their systems to have a return temp of <target temp> + dT ...
so conversly, flowrate = heat / 4.18 / deltaT Using 6kW as power ('heat'), 6 / 4.18 / 8 * 60 (to get lpm) = 10.77lpm, or the 10.8 I quoted - nice. ...
@Richard24738 - how did this pan out?
Nudging this thread to see if any other Ecodan can share their experiences of their set up and how it behaves when heating water. [quote]Further...
- 27 Forums
- 2,750 Topics
- 64.7 K Posts
- 1,991 Online
- 7,157 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist Have you ran the numbers as to which ...
By Papahuhu , 45 minutes ago
-
RE: How Accurate Is My DIY Heat Loss Calculation?
D'oh - of course. I shouldn't post before my brain is f...
By Old_Scientist , 2 hours ago
-
RE: Questions about A2A for heating as well as cooling
@rob-of-york I would concur with the underfloor insulat...
By Toodles , 4 hours ago
-
RE: New Vaillant Arotherm controls link to existing thermostats ; wired vs wireless
Nothing attached! I have rads but UFH makes the case ...
By JamesPa , 4 hours ago
-
RE: Cooling with air to water heat pumps
Passive cooling should always be the first call. Keep ...
By JamesPa , 5 hours ago
-
RE: Do I add Air Con or MVHR to existing A2W ASHP?
@rob-of-york Thank you, I’m thinking along these same l...
By Toodles , 22 hours ago
-
@Mars Good questions! The downstairs unit did the maj...
By Rob of York , 22 hours ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@dave, I think @jamespa has probably identified the mos...
By Mars , 2 days ago
-
RE: Plug and play solar. Thoughts?
My thought is simple. Bring it on and bring on plug in...
By JamesPa , 2 days ago
-
RE: Heat Geek mini store vs pump size
Yes I agree, that’s why Heat Geek have most likely sele...
By Tomtheheatingengineer , 3 days ago
-
@tomtheheatingengineer, thank you, and welcome to the f...
By Mars , 3 days ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
@majordennisbloodnok @tomtheheatingengineer For my ...
By JamesPa , 3 days ago
-
RE: Is the "divide by 2900" rule still valid?
Really flow rate is a pipework limitation not a water p...
By JamesPa , 4 days ago