RE: Heat pumps and on/off working - starting to quantify it

does anybody have idea how much extra electricity is used from having house at 22 instead of 21. Women are cold creatures. 10%?

1 year ago
Reply
RE: Heat pumps and on/off working - starting to quantify it

Probably the most important discussion in heatpump usage. Nearly all installers just put in stats and leave them turn off and on the heatpump at will...

1 year ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

Just last update, turns out a small number alterma2 hps left factory with room frost protection enabled when i should be disabled,enabled on older mon...

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

anyway ext rt was ok. Happened again this morning at 6am, only noticed which proves my point no call for heat, thermostat main a is off when this is h...

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

Has the system been told to refer to EXT RT ( this can be found in installer settings, System layout, Standard, Control method ) assuming your using 3...

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

@derek-m Sorry that's my irish way, i mean its unlikely coming on because i have only 1 dhw schedule? I tried equilibrium adjustment at daytime and 11...

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

Hardly coming on because im only using 1 dhw schdeule now? I took off reheat.

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

Good Morning A sensor out of range could cause this but also the unit does like to use the BUH if the outdoor is close to the time out range in DHW...

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

@derek-m set back few weeks ago, maybe 3. January was pretty cold too around here.

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

@derek-m Only changes made were altering dhw schedule and opening living area loops. If i hear back from plumber ill update here. I cant login to my s...

2 years ago
Reply
RE: Numerous issues – 11kW Daikin Altherma 3

3am again, woke up to it,same issue, had to switch off at fuse box in plant room. Rang plumber who serviced it in January, cant understand it, he is g...

2 years ago
Page 11 / 20
Share:

Join Us!

Heat Pump Dramas?

Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.

Pre-Installation Planning
Post-Installation Troubleshooting
Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)

👉 Book a one-to-one consultation now.

Latest Posts

Members Online

x  Powerful Protection for WordPress, from Shield Security
This Site Is Protected By
Shield Security