Last seen: Sep 10, 2025
@pie_eater I'm just offering my 2 cents to say I agree with the comments - your installer sounds a wee bit er... flakey. MCS guidelines are exactly ...
@derek-m So I can't just compare the delta T @ 30 for both rads? Oh. my. days... I think I need to go to college for this. Back to playing with Heat ...
@jamespa I'm using the Delta T watts for both - proposed K22s and my existing K11s. Is that not right? 🙈 One designed for 50º flow temp the ...
I have just discovered that BOTH my installer's heat loss proposals for 4 kw Daikins (based on imaginary heat loss and imaginary fully insulated walls...
This is such a good analogy - it has really helped me to see the problem. I didn't realise that higher inside temps meant more heat loss. I don't kn...
@jancold Me too! 😁
@heacol thank you Brendon - that's helpful. BG want a buffer tank Octopus want a volumiser. To be fair, I didn't push back on the buffer with BG ...
@derek-m Thank you. If you get time please either have a look at the images I put in a post roughly a page back. Or see below: I got a link from Op...
@gunboatdiplomat I was being a muppet, sorry. 🤦🏻♀️ The Heat Geek guesstimate is double the Octopus quote for a...
@derek-m Thank you - that's great imagery - I have that kind of a visual brain so it appeals. I will play with it this weekend and have a go at tryi...
@derek-m I 2nd that and keep it slow and agonising for cavity wall insulation sharks. 🤬
@bontwoody Theirs (from your link) is even lower than the MCS calcs. HG = 3kw BG = 3.5kw Oct =4.? These are all estimated ...
- 26 Forums
- 2,158 Topics
- 47.4 K Posts
- 42 Online
- 5,736 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
That's a valid point, of course nobody wants the inconv...
By downfield , 21 minutes ago
-
RE: What crazy nonsense are inverter limits and why are they imposed?
For best results with induction hobs use stainless stee...
By Scalextrix , 34 minutes ago
-
RE: Who’s Caved and Switched the Heating On Already?
Central heating still switched off and will be until Oc...
By AllyFish , 3 hours ago
-
RE: Is a Valliant Inline 6kW heater a BUS buster?
Please read to the very end of this post, I shift my po...
By JamesPa , 3 hours ago
-
RE: COP is not the only measure of efficiency
We keep all our TRVs fully open using the whole house a...
By Old_Scientist , 3 hours ago
-
RE: Midea ASHP – how to set weather compensation
I think it is a bug in the code, it comes on even when ...
By cathodeRay , 17 hours ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
I am pleased to say at 4pm today we have added another ...
By ASHP-BOBBA , 19 hours ago
-
RE: Buffers, hot water and cooling
@jamespa Your reasonably close! Especially with warmer ...
By dgclimatecontrol , 21 hours ago
-
RE: Renewables & Heat Pumps in the News
To unpack this a little.... 1) how many of us in this...
By Lucia , 1 day ago
-
RE: Vaillant aroTherm Plus 10kW thoughts?
@realevil the fans and fan speed / coil size (height, w...
By ASHP-BOBBA , 2 days ago
-
RE: Mitsubishi Ecodan 11kw Defrosting Issue.
@morgan this can just be done by your sepecilist when t...
By ASHP-BOBBA , 2 days ago
-
RE: Anyone still weathering it out with Agile?
@toodles I guess it all comes down to import averages. ...
By Tim441 , 2 days ago
-
RE: 300 Liter Tank - Do I have to heat it all?
The size of DHW tank affects the anti-legionella cycle....
By Transparent , 2 days ago
-
RE: Heat Pump SCOPs – The Truth Might Not Be What You Think
@scalextrix Name plate capacity
By HCas , 2 days ago
-
RE: Solar Thermal DHW and ASHP
I was originally contemplating a solar thermal installa...
By jamespetts , 2 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
My system installed in July 2024 has produced 6.4mWh in...
By jamespetts , 2 days ago
-
RE: A Customer's Lessons Learnt from a Heat Pump Installation in a Large House
@judith thanks for your suggestions. Starting from col...
By GrahamF , 3 days ago
-
RE: Inventor (Midea) Heat Pump short cycling advice
I switched to "fan coil mode" to be able to set water t...
By immunity , 3 days ago
-
RE: DESNZ doing a survey which asks the right questions!
Without a survey their only source of data is probably ...
By JamesPa , 3 days ago