Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 15, 2026
Topics: 27 / Replies: 5236
Reply
RE: Commencing on an ASHP Installation Process

If that is the case then I would add to my earlier post: I would try to avoid getting a heat pump now that will be significantly oversized once the...

1 year ago
Reply
RE: Commencing on an ASHP Installation Process

I'm not sure expecting consensus is realistic as the solution, given the conservatory situation, depends as much on your preferences and use patterns ...

1 year ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

Thanks for that thoughtful reply. Unfortunately we get far too many reports here where 50l 4 port buffers have been installed 'because that's what ...

1 year ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

@damon thank you for posting. Would you care to tell us in what circumstances you fit a buffer tank, why, and how you set it up to avoid a cop penal...

1 year ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

... but a volumiser would prolong run times by the same amount without any of the downside risk in performance, difficulties with fault diagnosis and ...

1 year ago
Reply
RE: Planning Update: 1 Metre Boundary Rule for Heat Pumps Has Been Scrapped

This is indeed welcome news. In addition the new legislation: Increases the maximum volume under pd to 1.5cu m other than for flats where it remai...

1 year ago
Reply
RE: Is Your 6kW Air Source Heat Pump Really a 6kW?

That's my point really, it should be both freely and readily available. As you say it's just a table (or set of graphs) of cop and output vs ft and o...

1 year ago
Reply
RE: Is Your 6kW Air Source Heat Pump Really a 6kW?

In fairness to heat pump manufacturers the output inevitably (unless artificially restricted in software) varies with oat and FT. Furthermore the vari...

1 year ago
Reply
RE: Yes, the "zoning with ASHP" topic again...

Thanks for the detailed reply and I apologise if I can sometimes be pedantic and determined to 'get to the bottom' of product claims. My aim is simply...

1 year ago
Reply
RE: How To Balance Radiators & the Role of the Lockshield Valve: A Homeowner's Guide

Really delighted to hear that. I can't comment on homely but if you don't have it then you will likely want to readjust your weather compensation cur...

1 year ago
Reply
RE: Plate heat exchanger considerations

Work on 2-3 percent per degree. This is a reasonable estimate of the reduction in COP because you will need to run the heat pump at a higher tempera...

1 year ago