Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 15, 2026
Topics: 27 / Replies: 5233
Reply
RE: Remaining hot water/hot water flow meter

Rainfall showers can be 20l/min and stored water at mains pressure/3bar generally flows faster (possibly a lot faster) than anything coming out of a c...

1 year ago
Reply
RE: Flow Rate & Low Loss Headers

tricky that, I cant say I have a solution. Fair enough. Its all a bit crazy IMHO. You can have a 13kg bottle of propane in a garage or on...

1 year ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

@ashp-bobba Talking of over-sizing (and if you dont mind me asking) what do you suggest for a load such as 3-4kW. There is another thread where this...

1 year ago
Reply
RE: Flow Rate & Low Loss Headers

I definitely wouldn't want that near my bedroom (which is where my DHW tank is) but as you say in a kitchen area is OK Lots of installers certain...

1 year ago
Reply
RE: I don't need any heating in the summer. How do I turn my Samsung heat pump off?

Q1 - Yes, thats why the tank is well insulated, the amount of energy lost is pretty small. That said, as you know when you use most DHW, why not do s...

1 year ago
Reply
RE: Remaining hot water/hot water flow meter

You could do a sensor near the top (it would need to be inside the insulation so can you get at it and how would you use it to signal you) but there i...

1 year ago
Reply
RE: Thinking of ripping our my IVT Greenline HT Plus C model and replacing with a gas boiler.

That's great and in principle I wouldn't disagree, but if someone is being quoted 18K to fix a heating system then I can fully understand their reluct...

1 year ago
Reply
RE: Air Changes per Hour - ACH and the MCS requirement

@ashp-bobba My personal perspective on this, based on my own experience and the sad stories I read on this forum, is that the industry as a whole (I'm...

1 year ago
Reply
RE: Thinking of ripping our my IVT Greenline HT Plus C model and replacing with a gas boiler.

What's to stop you simply replacing the heating bit with an ashp. Presumably all the emutters etc are fine so it's just a straight swap of heat sourc...

1 year ago
Reply
RE: Flow Rate & Low Loss Headers

Further to the above I found the Aurora/AdlerCastra user Manual Page 4 concerns me, the WC curves are stepped as a function of OAT not smooth and...

1 year ago
Reply
RE: Flow Rate & Low Loss Headers

Not detrimental just superfluous and something else to go wrong, but I cant understand why its more expensive, cylinders with integral heat pumps aren...

1 year ago