Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 13, 2026
Topics: 27 / Replies: 5231
Reply
RE: New build installation query

Nice neat plumbing job! I cant see the plant room on the rather low resolution plan. Where is it? Also the key drawing 12327-1000030975 is too lo...

10 months ago
Reply
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂

ah - not the greatest routing. Is it possible to insulate and/or isolate the pumps from the structure?

10 months ago
Reply
RE: Mitsubishi Ecodan R290 10kW performance

Not sure I agree with that. Thermodynamically lower deltaT=higher average emitter temperature for any given flow temperature = lower FT needed at t...

10 months ago
Reply
RE: Mitsubishi Ecodan R290 10kW performance

This looks odd: Heat transferred = F*DT*.0633=18*3*.0633=3.4kWPower consumed = 2.4kW   3.4kW delivered to the house is not unreasonable at ...

10 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

I think there may be some oddities about the COP reported by the app at present and possibly going forward. My app (v3.31 build 24435) no longer se...

10 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

Is it still cycling, at what FT/OAT? Mine appears currently to be at the 'sour spot'. OAT about 11C, still just cycling, COP 3.9, target FT ~32. I...

10 months ago
Reply
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂

Is it possible there is air still trapped in the system. Mine took a month to clear and despite the presence of an auto bleed valve one radiator need...

10 months ago
Reply
RE: Mitsubishi Ecodan R290 10kW performance

I cant remember what Ecodan reports but some heat pumps report energy consumed and environmental gain. In this case cop = energy consumed/(energy co...

10 months ago
Reply
RE: One room is colder than the rest of the house

I would personally be sceptical about reaching any conclusion that goes against the norm of heat pumps. In the end the Cosy is a heat pump, subject t...

10 months ago
Reply
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus

If you paid for any of the assessments try asking for the full calculation. I did for the one I paid for, very useful.  

10 months ago
Reply
RE: Radiator Question

@drei Thats a nice designer radiator which it would be a shame to bin, and the space is otherwise useless. That said vertical panel radiators dont...

10 months ago