Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Jun 10, 2026
Topics: 25 / Replies: 4955
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

With that drop its clear that very little hot water is getting from the primary into the secondary so either pump problem or piping problem. Has he p...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Really sorry to hear this, I was expecting no change not a deterioration and I must therefore eat humble pie following my comment that swapping a smal...

7 months ago
Reply
RE: Help me keep the faith with my air source heat pump installation

made of brass not plastic, proper square hole same shape as bleed screw. I did a quick search and they seem relatively rare, most seem to be a (pres...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Definitely. 8C DT is higher than the default design DT for most heat pump systems which is 5 This has the effect of reducing the average flow temp b...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Thats a great analysis and |I doubt any heat loss calculations adequately deal with this. Put another way there is an (probably) unaccounted for loss...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Thanks. I had forgotton that particular feature. I presume the call for heat switches secondary pumps on/off not the heat pump. All of this is goi...

7 months ago
Reply
RE: Daikin Short Cycle Query

Its the heat pump, more specifically the compressor, cycling on/off quickly. The most important parameter is the on time, anything less than about 1...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

It will inevitably. If your heat pump capacity is perfectly matched to your house loss you can expect the heat pump to cycle from an OAT of roughly 1...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

re 'enforced night mode running constant at 60%' are you saying that the heat pump was previously forced on (at 60% modulation) at night. If so thats...

7 months ago
Reply
RE: Daikin Short Cycle Query

With the expanded view you can see it ticking along at about 300W other than during the DHW reheat and between 4.30 and 5am. The spikes are very narr...

7 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

OK, couple more questions At these relatively mild temps, how certain can you be that its not just a WC setting problem that would be resolved by le...

7 months ago
Reply
RE: Daikin Short Cycle Query

Hmm   The spikes are very short (so quite possibly very little energy and thus of little significance) but too low to be just the water pump....