Was there any more detail or it that it? Its over 8kW, and by the time they make an allowance for DHW they would be able to argue for 12kW based on t...
I have to agree that in many cases ToU tarrifs will dominate. I guess I should've framed the question as 'in the absence of ToU tarrifs!
Not sure about this. The heat pump sees the water returning from the fins, which will be at a temperature determined by the defrost process not any t...
Not sure about this. The heat pump sees the water returning from the fins, which will be at a temperature determined by the defrost process not any t...
@eliuccio Unfortunately, whilst I agree with a lot of what is said above, I dont agree with all of it. For clarity: Firstly Whilst I agree t...
Whilst I agree with the final conclusion (flow side placement appears to be best, perhaps with the exception that if the volumiser is outside the insu...
It makes sense, although shows a complete lack of thought on the part of the designers (which is disappointing) about the things that they could do, w...
No need for apologies, just cautioning about getting too hung up on all of the mistakes (of which there appear to be plenty enough to make a case) and...
Definitely its in the 20xx FSVs. Conversely it may be that you need to reduce 2022/2032 further as well as changing 2093 so it operates on pure WC. ...
@sunandair I don't want to get embroiled in an argument, but I am interested in finding a tolerably robust answer to the question that can be applied ...
I think most heat pumps have this mode but I cant see how it can reduce cycling, unless there is something weird in the control logic (which is possib...
- 26 Forums
- 2,275 Topics
- 50.9 K Posts
- 210 Online
- 5,936 Members
Join Us!
Podcast Picks
Latest Posts
-
Herewith a plot of flow rates during the last 36 hour o...
By Toodles , 29 minutes ago
-
RE: Samsung Gen6 and Havenwise ........
I am no expert on this but on your gen 6 controller onc...
By Alfapat , 6 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk these are called roll top rads, they were still ...
By AgentGeorge , 7 hours ago
-
If the Vaillant is a 7kw unit I’d avoid. Quiet outside ...
By AdamK , 7 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
So its clear temps are downward trending. Suspect night...
By Crimson , 8 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
It has it's uses and there is no way I could have set t...
By benson , 18 hours ago
-
RE: Oil Boiler & Heat Pump Hybrid System
Thanks for the suggestion, but farmhouse is grade 2 lis...
By paultheheating , 1 day ago
-
RE: My DIY Heat Pump installation
This is very kind. However software is not really my ...
By Polar bear , 1 day ago
-
RE: Request for feedback on where we're at with our quest to get an ASHP or ideas.
thanks, heatpunk looks great, being able to do the calc...
By giryan , 2 days ago
-
RE: Is Your House Warmer Upstairs Than Downstairs?
Why arent you expecting them to make much difference. ...
By JamesPa , 2 days ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
It has been just over a year since we changed over to a...
By npru , 2 days ago
-
RE: Finding a Thermostatic Shower Valve That Works with Heat Pump Systems
@morgan I should just have written ‘Mea Culpa’ shouldn’...
By Toodles , 2 days ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
'We learn from history that we do not learn from histor...
By Lawrence Leask FInstR , 2 days ago
-
Mitsubishi Ecodan FTC7 Legionella date set
I can set the number of days between Legionella cycles ...
By DRB01 , 2 days ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
@treewizard Yes, I like the extra facilities that NetZe...
By Toodles , 2 days ago
-
RE: My Octopus Cosy 6 Heat Pump Journey: From Quote to Completion
@editor thanks for highlighting my name. Yes I did get ...
By Chansug , 3 days ago
-
RE: balancing radiators with a mixture of different size pipework and a few undersize rads.
@editor Thanks for your input Mars. No I think the comm...
By baxtDave , 3 days ago
-
RE: Rate the quality of your heat pump design and installation
We’re looking to expand our list of recommended list of...
By Mars , 3 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Along with the right workers, they can’t b...
By Toodles , 3 days ago