not a massive surprise. if the external unit has power but no comms to the internal unit, and it knows that its "cold out", one might reasonably suppo...
I think you'll find it quite hard to tell based on either poking radiators, or long term data. There are lots of spikes in the "HP temperature" that ...
@dannymoss23 its not that exciting... you can't not have one ! they're absolutely standard required items , your system wouldn't work at all without o...
@dannymoss23 an air vent looks something like this and will be at the top of any high points in the pipework . definitely should be one around your...
@dannymoss23 PP will just be running slower, thats why its gone quieter. check your flow rate, it may be lower than you want.
@dannymoss23 so they've used the proper method as far as I can tell to get out the garage wall to the ASHP (big hole, insulation through hole, pipe t...
@tobyg the vast difference between your gas usage and their estimate is a significant concern. also, a gas boiler is at best 85% efficient. so your me...
@dannymoss23 yes although that is interior grade insulation. It needs to be exterior grade thickness in any unheated space, so the easiest it just to ...
@dannymoss23 no worries. copper pipe will transmit vibration to any hard surface its in contact with, particularly one carrying a high flow rate such ...
@dannymoss23 for the run under the floor inside, the pipes need moving further apart so there is room for interior grade lagging. they may possibly ne...
@dannymoss23 28mm pipe : thats good. but I can see the issue. the pipe goes through a hole in breeze block thats only just bigger than the pipe . wi...
@dannymoss23 noise: so seems like you have 2 pumps a primary-side and a secondary-side. which is common. I wouldn't expect there to be a 3rd one. ...
- 26 Forums
- 2,242 Topics
- 49.9 K Posts
- 404 Online
- 5,903 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Midea ASHP – how to set weather compensation
@cathoderay I've attached a sample of the data I have (...
By pash44pump , 3 hours ago
-
RE: Faulty Clivet heat pump out of the box
We would never win these projects as we spend 1 whole d...
By ASHP-BOBBA , 4 hours ago
-
RE: Ecodan Melcloud Temperature Change
@gruff2001 - if set on WC, the app is only communicatin...
By ASHP-BOBBA , 4 hours ago
-
RE: End of Summer Time Reminder to Ecodan owners
@morgan did the system time change last night? if so y...
By downfield , 6 hours ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@toodles indeed. the question of proof will only get ...
By Tim441 , 8 hours ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
@jords were you not given a copy of the full heat loss ...
By Chas Barry , 10 hours ago
-
@eliuccio Sometimes changes in electrical regs only app...
By Toodles , 10 hours ago
-
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?
I signed up here due to finding this question via a Goo...
By Unsure , 10 hours ago
-
RE: Mitsu PAR-WT60 Wireless Controller
Aslo, subject to FTC version, Your thermostat will cont...
By ASHP-BOBBA , 13 hours ago
-
@bontwoody Thanks for the info. Quite a spread of value...
By springswood , 14 hours ago
-
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂
Thing is it is one of those intermittent things. Yes I ...
By Jancold , 14 hours ago
-
@transparent Yes to questions 1 to 3. Also, yes to the...
By Morgan , 14 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
OK thats cheap, the commercial price seems to be £400 p...
By JamesPa , 2 days ago
-
RE: Solar inverters - where does the energy go when clipping?
I think I must query the sources on which Greenmatch ha...
By Transparent , 2 days ago
-
RE: Replacing knackered oil boiler with Samsung ASHP - Perthshire
This is how I run my Samsung 12kW ASHP with a 3rd party...
By Old_Scientist , 2 days ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
@cathoderay thanks- yes will keep an eye out for the de...
By benson , 2 days ago
-
RE: Renewables & Heat Pumps in the News
Hoping so as well! I am no specialist. The language use...
By Batpred , 2 days ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@old_scientist Just to say that during our retrofit, we...
By Toodles , 2 days ago
-
RE: Daikin Altherma 3M ASHP and British Gas Hive Home
We have a Daikin EDLA08 8kW monobloc (DHW is handled se...
By Toodles , 2 days ago