Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Jan 14, 2025
also its worth saying, the PWM pump is not the enabler to run at low flow temps. That comes from having big enough emitters, properly balanced, etc. ...
@ecobaker mine did not need a firmware change. the PWM worked first time. I am not even sure how you would go about getting a firmware change done. ...
@bontwoody it will run at 35, but only stably if you have enough emitters to balance the min output of the HP. Which in my case with a 16kw gen6 unit...
probably about a grand's worth as well. which could have been not spend during the original install. its not just for laughs that we keep banging on...
@ecobaker you might want to check that the right valves are open and not open when wanted. I suggest drawing a plumbing diagram and a wiring diagram a...
@ecobaker the description of what the system did makes total sense if there was nothing running round the rads. as you have an LLH you need the second...
physics says that if you know what flow rate the existing circulation pump is running at, its power level, and the characteristic curve of the pump (w...
there is one G6 8kw on HPM.org, here , low point seems to be about 2.5kw. The owner of that one might be on this board as well, I can't remember. ...
@ecobaker so... your points, summarised. the guides you need are all here. type MIM-E03CN into the search. the MIM controller manual has all the p...
@editor I did look at 3 phase, it was painful, got quoted 10k just for the DNO piece. and that was for tapping into the phases that's only 5 metres aw...
@jamespa I was wondering if you might say this 🙂 . those who've self installed have , generally speaking, installed in such a way that is compliant ...
@ecobaker if its in the airing cupboard it'll be no use, you need to move it to a living space to use it as the stat. Two wire low voltage so easy to ...
- 26 Forums
- 2,622 Topics
- 61.2 K Posts
- 1,196 Online
- 6,999 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Heat Pump Pipe Sizing Question
Like with some other minor mistakes made, this is somet...
By ASHP-BOBBA , 5 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@editor It's available here -
By HarrisonC , 6 hours ago
-
@mjr completely fed up with the AI drivel flooding soci...
By Mars , 6 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
The wind didn't blow the hot air balloon the most direc...
By mjr , 9 hours ago
-
@painter26 i am in Lightwater and midea trained. Sounds...
By Wizard , 9 hours ago
-
RE: Renewables & Heat Pumps in the News
@jamespa, for all I know they did have the coupling and...
By Mars , 12 hours ago
-
@andrewj ... well, clearing gutters is a worthwhile ann...
By colinc , 13 hours ago
-
RE: Anyone concerned about GivEnergy?
Here is the latest communication from GivEnergy regardi...
By txmartyn , 17 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Can @editor please clarify: Does the Indevolt App com...
By Transparent , 17 hours ago
-
@editor I too had a long list of questions, some of ...
By Bash , 18 hours ago
-
RE: Tell us about your Solar (PV) setup
3.84kWp of solar on our main South-East facing roof, in...
By Gmuzz , 18 hours ago
-
RE: Mitsubishi Ecodan FTC6, Evohome & Economy 7. Getting Two Zones to Work Together
Lets step back. Why do you need/want 2 zones? The hea...
By JamesPa , 20 hours ago
-
RE: Vaillant arotherm plus heat pump frost protection
Yes, typically as close to the heat pump as possible. ...
By JamesPa , 20 hours ago
-
RE: Brown Oily Residue Blocking Air Vent and Weeping Relief Valve... Anyone Seen This?
Difficult to comment further without being there. If...
By JamesPa , 1 day ago
-
RE: Our 10 year old Grant heat pump failed
Back in the 70’s and through the eighties, one of my re...
By Toodles , 2 days ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
@seoras Sorry to hear that. I found Vaillant very help...
By JamesPa , 2 days ago
-
The Watchdog That Watched and Waited
On 9 January 2026, Consumer Energy Solutions collapsed ...
By Mars , 2 days ago
-
RE: GSHP Kaput After 16 Years: New Compressor or Switch to ASHP? Advice Welcome
Cool Energy in Grimsby sell ground source heat pumps an...
By DerekDeLeon , 2 days ago
-
RE: Valliant Heat Pump Settings
Thats arguably a sign of a good installer - they unders...
By JamesPa , 2 days ago
-
RE: Electricity price predictions
Well, we have so many cases where rain water mixes with...
By Batpred , 2 days ago
-
RE: Two heating zones to one zone
@profzarkov They arent obviously wrong, but the only...
By JamesPa , 3 days ago
-
RE: Towns water feed to air source heat pump system
The DHW circuit cant be separated (well it could, you c...
By JamesPa , 3 days ago
-
Solis AC-coupled 3kW storage inverter
Solis AC-coupled 3kW storage inverterPylontech batterie...
By MartinRobinson , 3 days ago
-
RE: My NIBE ASHP Nightmare: No Commissioning, High Bills and a Hostile Installer
As @transparent has observed above, this is not bad, an...
By cathodeRay , 3 days ago