Last seen: Sep 19, 2024
@newhouse87 I will try to reply sometime tomorrow. What is the size and type of your home? What is the model of your heat pump? Do you have radiat...
Did your installer come riding a horse and wearing a 'ten gallon hat'? 😋
@cathoderay It would appear from your 0x04 test, that the first byte within the message body indicates the body type, then either the body length is...
What happens if you add byte_17 to byte_25?
@cathoderay When you first discovered the type 04, notify1 message, was the data obtained as provided by recent messages, or did you manage to obtai...
It is not possible to select a particular output, they are included within the test data to indicate the likely power consumption and efficiency when ...
@cathoderay I have also been trying to figure out where the message type, and hence structure is being selected within the code. Looking at the he...
@cathoderay I have been doing some further investigation into the structure of the message body with the following results. The actual length of the...
When you checked the message length, did you add additional items to the requested list? If not it could be just supplying the requested items and hav...
Having possibly increased the size of the body type from *18 to *25, it may be useful to try adding bytes 23, 24 and 25, to see if the body type has a...
Yes that's fine.
@cathoderay A further test would be to change all occurrences of 'tank_actual_temperature' to 'byte_21' to see if it still produces data for 'tank_a...
- 26 Forums
- 2,171 Topics
- 47.8 K Posts
- 24 Online
- 5,744 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Help me keep the faith with my air source heat pump installation
@jamespa if I remember the insulation has a notch cut i...
By AdamK , 46 minutes ago
-
RE: Big Changes Coming to Our Heat Pump System
Me too, but still some people look at me as if I'm mad....
By JamesPa , 2 hours ago
-
RE: MCS certificate SCOP vs real-world performance
That may be contributing to lower than expected SCOP. ...
By JamesPa , 2 hours ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
This is the sort of thing I mean. I've added the T1S va...
By benson , 3 hours ago
-
-
RE: Mitsu PAR-WT60R Wireless Controller - options
How it does it's job is something of a mystery although...
By Abernyte , 9 hours ago
-
RE: Powerwall 3 or Myenergi or something else?
Yes I was thinking of outdoor, IP65 batteries with buil...
By Temperature_Gradient , 13 hours ago
-
@jamespa Thanks. Yeah any adjustments Ive made at pr...
By cliffhanger , 16 hours ago
-
RE: How to choose Towel Rails for an ASHP
@rob-nezard yes absolutely. Here is the link and a pho...
By GrahamF , 2 days ago
-
@mixergy Thanks for the update, I would appreciate some...
By bontwoody , 2 days ago
-
RE: Is Your Broadband Router the Weak Link in Your High-Tech Home?
Unfortunately I'm not that well connected 😂 ...
By Scalextrix , 2 days ago
-
RE: A Customer's Lessons Learnt from a Heat Pump Installation in a Large House
It is interesting to see what our new Grant Aerona 290 ...
By GrahamF , 3 days ago
-
RE: Midea ASHP – how to set weather compensation
I noticed that too and thought the same thing, but then...
By cathodeRay , 3 days ago
-
RE: Ya can’t win! It is S*d’s Law!
@old_scientist If IOF is still running next late spring...
By Toodles , 3 days ago
-
RE: Electricity price predictions
Those of you on Agile will do well tomorrow; there are ...
By Toodles , 3 days ago
-
RE: Who’s Caved and Switched the Heating On Already?
We've been running our Ecodan system, installed in June...
By Sheriff Fatman , 3 days ago
-
Ok. Two schools of thought. The first is to run the ...
By JamesPa , 4 days ago
-
@drei Willing as I am to help, I don't think I'm yet ...
By JamesPa , 4 days ago
-
Selling 5 year old ASHP & Gas Combi Boiler - £590
Selling a 5-year-old Daikin Altherma Hybrid Air Source ...
By Paul G , 4 days ago