@newhouse87 I forgot to mention. Have a look at the manual for the controller, there may be an icon on the controller display which indicates if the...
To test if this is the cause of energy consumption, set the temperature down so that the heat pump stops, as you do with the overnight setback, then i...
But at least the applicator is easy to take apart and clean now. 😋
Try lowering the heat pump DHW setting to 50C, and raising the iBoost setting to 60C.
@iantelescope Why TWICE? Did they allow him to rejoin after slapping his wrist? I would suggest that you record the temperatures around your heat ...
I would hope there would be a label fitted somewhere stating the concentration of anti-freeze added, if that is the case. If not contact your installe...
This is an extract from the manual. 7.6.4 To protect the water circuit againstfreezingFrost can damage the system. To prevent the hydraulic componen...
Look through the controller settings and see if the BUH is enabled and the value of any temperature setting.
The rating should be specified somewhere in the manual. What does the manual state about when the BUH should operate?
Is the BUH rated at 6kW and is it enabled?
Did the outside temperature actually go below zero? Do you have a backup or booster heater installed? Check through all the controller settings to...
What are all the readings on the controller telling you? Have any sensors failed?
- 26 Forums
- 2,367 Topics
- 53.7 K Posts
- 216 Online
- 6,042 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Help needed with Grant Aerona 3 issues
Noted. Its a pity you didnt capture the flow rate and ...
By JamesPa , 3 hours ago
-
RE: Best Heat Pump Brand in the UK
Last Call to Vote & Win! Haven't voted for your Hea...
By Mars , 3 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Interesting question. To be frank, since I have no inte...
By Majordennisbloodnok , 10 hours ago
-
RE: Changing from 4-port buffer to volumizer
@andy1618 see the very sage advice from @editor above. ...
By JamesPa , 20 hours ago
-
RE: New Fogstar 15.5kWh upright solution
The video shows the JK balancer, but the connection of ...
By Batpred , 22 hours ago
-
RE: Ecodan unable to hit legionella target temp - what's the consensus?
@9jwr9 Hi, yes this is the issue with every (stand alon...
By ASHP-BOBBA , 23 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk FWIW I managed unintentionally to 'coax' mine in...
By JamesPa , 1 day ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
You are in essence right. Adia only works with selecte...
By JamesPa , 1 day ago
-
No, you haven’t missed out, @batpred. This thread’ll st...
By Majordennisbloodnok , 1 day ago
-
RE: Tesla Powerwall – More of a ‘Luxury’ Than an ROI Winner!
Also, though they weren’t prepared to match the price t...
By Toodles , 1 day ago
-
RE: How long will your energy contract last?
My INTELLI-FIX-12M-25-08-29 has less than 12 months to ...
By Batpred , 1 day ago
-
RE: GivEnergy 2025 forthcoming batteries and inverters
Then, perhaps @toodles , you should've made a submissio...
By Transparent , 1 day ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I am wondering if anyone with an EV could find the 7p/k...
By Batpred , 1 day ago
-
Possibly, but it would also reduce DeltaT across the em...
By JamesPa , 1 day ago
-
RE: ASHP sizing - value of Heat Transfer Coefficient
@cathoderay It was reminiscent of the BBC Open Universi...
By Toodles , 1 day ago
-
-
@morgan They are unsupervised these days, can’t get the...
By Toodles , 4 days ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 5 days ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 6 days ago