@derek-m findings as follows- Tank DHW reading 50 degrees- green pump hot and vibrating Thermostat removed- dropped to 21, when water star...
@iancalderbank 👍🏻 Thank you!
@sunandair thanks so much for your message. I’ve set the parameters wider for re-heating this evening so will see. I can’t find the setting for ‘large...
@derek-m I’ve checked the pipes under sink in kitchen and bathroom but they are not hot until I run the hot water. Even with the pump on it sometimes ...
@derek-m see pictures-
@derek-m thank you. I believe the green pump at the top of the cylinder is for the hot water. I m not sure how to check if it’s running but it is maki...
@allyfish thank for your reply. There are 3 of us- 1 shower in the morning and 2 evening- not more than 5 mins but they are rain shower heads. A bit o...
@derek-m thank so much for your reply. I really do appreciate it. I’ve attached some photos- let me know if you need anything else. I think one of the...
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 152 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
@majordennisbloodnok I put this question into Perple...
By downfield , 36 minutes ago
-
Which is one reason why I now talk about the economic s...
By JamesPa , 2 hours ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 3 hours ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 6 hours ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 12 hours ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 13 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@andrewj they will release smarter controls, its been m...
By swwils , 16 hours ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 16 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 18 hours ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 20 hours ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 21 hours ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 22 hours ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 1 day ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 1 day ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 2 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 2 days ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 2 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 3 days ago