Last seen: Aug 11, 2025
I think you are right, and it happens after a HA restart as part of a handshaking routine: 2023-03-07 13:13:54.187 DEBUG (Heat Pump (LAN)) [custom_c...
@derek-m - you have certainly cracked the header. But there is still in my mind the question of how does it know that self._device_type is c3 (a heat ...
@derek-m - I've just done another extensive online search for something, anything that might give us a clue as to how to access other messages beyond ...
@drew-pa - here's the file. It is rather brutal and not very pretty, but it does the job. I've tried to add enough notes to make it clear what I did, ...
Where did the 3.2 come from? Good question, I should have said. It is about what my COP has been for the whole of this heating season, ie from beginni...
@derek-m - I think it was probably OK. I effectively made my weather curve level, with a low ambient end 36 degree LWT, high ambient end 35 degrees, s...
@derek-m - I got distracted an hour ago, missed the time but got it at 1800: 1757: dropped lower ambient end of weather curve from 58 degrees to 36...
I think that will be the simpler way to test it, but I will have to be careful with the timing, as I only get one reliable 04/04 message every hour, a...
It is what is shown in the chart, I have been logging it into HA for several days. It is the value after hex2dec conversion of the byte in 'location' ...
I think you are right, well done! The available range for set DHW temp on the wired controller is 20 to 60 degrees, which matches the dhw_temp_min and...
That suggests you are doing this online, on github, which does make tracing things easier. Outdoor_temperature is certainly real, in that is corresp...
- 26 Forums
- 2,129 Topics
- 46.7 K Posts
- 27 Online
- 5,651 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Octopus Cosy & Octopus EV + bidirectional smart tariff, together. What, eh?
@old_scientist me too. Just installed my new heat pump ...
By Eliuccio , 3 hours ago
-
RE: Is your heat pump insured?
Yup just spoke to Privilege to inform them of my impend...
By Scalextrix , 4 hours ago
-
Well by my reckoning based on the Flexible Octopus unit...
By Majordennisbloodnok , 4 hours ago
-
RE: Who's your electricity provider and what's your tariff?
@old_scientist I have had the first PW for some 2 years...
By Toodles , 4 hours ago
-
RE: Forum updates, announcements & issues
Just to keep everyone in the loop, as the site continue...
By Mars , 13 hours ago
-
RE: Fast DHW setting on Midea (Clivet) heat pump
@simon-w, is this something you could potentially assis...
By Mars , 23 hours ago
-
RE: Share Your Experiences with Heat Pump Manufacturer Support
Fwiw I called my installer out for the first time a few...
By JamesPa , 1 day ago
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
@sandy, I'll send Vaillant an email tomorrow and see if...
By Mars , 1 day ago
-
RE: Long term efficiency degradation
@jamespa yes as I thought thanks. We have a reaso...
By Scalextrix , 2 days ago
-
RE: Who has a V2G EV installation
I agree, but a word of caution. V2X is also sometimes u...
By Majordennisbloodnok , 2 days ago
-
RE: Sunamp Thermino Heat Battery
@jamespa A few days after the installation had been com...
By Toodles , 2 days ago
-
RE: Planning Permission May 2025
Fair enough. I have read the legislation and MCS020a ...
By JamesPa , 4 days ago
-
RE: How do I choose a single room MVHR to prevent losing heat in my bathroom ?
An update on the Heatsava. It is the most difficult thi...
By heat-pump-newbie , 4 days ago
-
RE: ASHP heat output monitoring
@carlo - not much better, is it. It looks more like a u...
By cathodeRay , 5 days ago
-
RE: Renewables & Heat Pumps in the News
this document extensively describes (in a non-blame, ne...
By Judith , 5 days ago
-
RE: Ecodan - Legionella Operation Time and Target Temperature
Once the white plastic cap is removed, my immersion loo...
By Old_Scientist , 6 days ago
-
RE: Replacing Refrigerant on Mitsubishi Heat Pump
@dgclimatecontrol I don't know, but they were not happy...
By DavidAlgarve , 6 days ago
-
RE: Why do we need pressurised systems?
A good question @toodles. My old open thermal store and...
By AllyFish , 6 days ago
-
RE: 300 Liter Tank - Do I have to heat it all?
Cross references for @martingale Background discussi...
By Transparent , 1 week ago
-
@ecobaker May I ask a question of you please. I too hav...
By Papahuhu , 1 week ago