Last seen: Nov 17, 2025
You should be fine, they are not complex queries, with the csv file(s) becoming the tables you select from. The sql 'dialect' is sqlite, which, as you...
Correct, the actual measurements (upper plot) shows some cycling on the LHS, the model (lower plot) does not.
What I do is have the data in csv format, which I can then load into a text editor, such as Notepad++, and extract slices at will. I also use python's...
I suspect a more accurate answer may be that D wants to paint a picture that has D and J as sage old chaps having a learned chinwag in the library whi...
@jamespa - the 'actual observed energy in value for the hour' is the value in the csv file for that hour. Its the equivalent of the observed deaths ov...
I described above what I plan to compare: expected vs observed energy in during periods with setback and recovery boost. The key thing I am trying to ...
I've got through the data, and while there were a fair number of WCC end point changes over last winter, they all happened mid winter, and the period ...
It should, the main complication with the covid deaths data is human behaviour, deciding what is and isn't a covid death, and those decisions, particu...
It will not. I am not persuaded you have read my recent posts describing what I am trying to do, or whether you have, and I have written them so badly...
@jamespa - at this stage, I am only looking at the relationship between energy in and OAT, and as the heat pump in normal WC no auto-adaption mode set...
@jamespa - as I pointed out, I expected spread, because this is all data, as it sits in the data file, and it is just a screening plot. All sorts of t...
A first quick plot, to see if I am wasting my time or not: all hourly data for the entire period I have data for, 25 March 2023 to date, OAT vs energy...
- 26 Forums
- 2,289 Topics
- 51.4 K Posts
- 431 Online
- 5,949 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Ah, that makes sense.
By AndrewJ , 8 minutes ago
-
Adia Therma - 'autopilot for heat pumps'
Thought I'd pop this one in here as the Adia proposal a...
By seatonian , 19 minutes ago
-
RE: Mitsubishi Ecodan R290 10kW performance
Don't know answer to final question. Your contract p...
By JamesPa , 53 minutes ago
-
RE: 10kw heat pump run in 24*7 data?
0.65. Heating curve of course depends on rad...
By JamesPa , 56 minutes ago
-
RE: New Fogstar 15.5kWh upright solution
Ah, it seems PACE BMS are easy to source on AliExpress,...
By Batpred , 1 hour ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
I have a gen 1 5kw Givenergy hybrid inverter and two ge...
By DCSH , 2 hours ago
-
RE: Ecodan ASHP Low COP and Unstable Compressor Frequency
@davidnolan22 Thanks for the graph. That's really us...
By lukewarmbath , 3 hours ago
-
RE: Vaillant water pressure gauge vs Analogue gauge
@jamespa Agreed I don't feel concerned about this, espe...
By jeegnesh , 3 hours ago
-
RE: Electricity price predictions
@jeff Keeping the ‘smash & grab’ installers who get...
By Toodles , 3 hours ago
-
RE: Heat Pumps Without Grants: Would You Have Installed One & Will You Now?
@toodles Yep, and it is not even a sticking plaster ...
By Jeff , 5 hours ago
-
RE: Renewables & Heat Pumps in the News
I agree, imperfect systems like voting for politicians ...
By Batpred , 9 hours ago
-
RE: Gov wants to alter our FIT contracts from rpi to cpi
The consultation is just part of the normal process for...
By Jeff , 9 hours ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@mairie - Your constituency member, Dr Zubir Ahmed MP, ...
By Transparent , 10 hours ago
-
@transparent @old_scientist Quick update, I submitted...
By Batpred , 1 day ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Lol. I know they CAN be calibrated, it’s just ...
By Crimson , 1 day ago
-
RE: UFH downstairs and radiators upstairs balancing question
Yes thats true, but that cant happen unless the room te...
By JamesPa , 1 day ago
-
-
Do Heat Pumps need to start up at Full Power?
When our heat pump starts up, (Daikin EDLA08 8 kW Monob...
By Toodles , 1 day ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
@colinc good luck with your project! UFH is the absolut...
By Judith , 1 day ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@hcas Just wondering if/where Ideal might be on your de...
By simonwig , 2 days ago