Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Aug 19, 2026
This is a bit of the outside unit not terrible was much worse before they came back to fix it as it was absolutely hideous. They had to do those to...
Soooo a bit more of a closer look. The board behind the buffer is screwed to the upright. Then the mounts on the back are screwed to the board s...
@transparent The installer just said set it to 50⁰ and leave thermostat on 21 no weather comp I had to set this up myself. He said this because t...
@hcas hi buddy, Sadly I have nothing to compare bills to say if it's better than gas or similar system. But hot water has been cheap to heat. ...
@transparent Thank you for your excellent break down of information this has blown my mind I will definitely get in and rummage deeper into what yo...
@johnmo in my case yes there are I made sure, they originally broke one and hard piped it but made them get a replacement Flexi.
My system makes a constant hum. Can't hear anything outside the house heat pump is mega quiet. Buffer mounted on a main joist and to a board on the ...
@transparent Cheers buddy, Well prepare yourself 😅 I've got a blocked radiator Small plastic pipes left in and old pipe re used when I ...
@gary I've got a Midea unit it's a big old thing but seems to be running well we shall see this winter will be out first living in the house with it
- 27 Forums
- 2,768 Topics
- 65.2 K Posts
- 2,099 Online
- 7,169 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Who's your electricity provider and what's your tariff?
@batpred When the raw material input has increased in c...
By Papahuhu , 53 minutes ago
-
We kept ours and Heat Geek would have been in touch if ...
By Batpred , 6 hours ago
-
RE: Missing flow temperature in Heat Geek proposal
The Heat geek contract had various get-out clauses with...
By Batpred , 8 hours ago
-
RE: Why are ASHP installs so expensive?
It seems a quite comprehensive breakdown. I will try to...
By Batpred , 8 hours ago
-
RE: Starting Our Heat Pump Journey: 1962 build 3 bed detached house
@ian-s I would encourage you to have a conversation ...
By Rob of York , 14 hours ago
-
RE: Is it the house or the equipment?
Thanks @jamespa The last hard to fix draughts in the...
By springswood , 15 hours ago
-
RE: Vaillant Arotherm – Using Heating
@l8again Mine is typically using 11w including the i...
By Batpred , 17 hours ago
-
RE: Next steps on my ASHP journey: Radiators and Pipework
If you have a flowmeter and two temperature probes, the...
By bobflux , 1 day ago
-
RE: Siting of the external sensor on a heatpump
@jamespa Absolutely. Even if the same mistake was mad...
By Batpred , 1 day ago
-
-
RE: Recommendations in Ely (Cambs) area for Full setup checks on Nibe HP setup for House.
In fairness all heating has cost a lot to run in recent...
By JamesPa , 2 days ago
-
RE: Navigating the World of Refrigerants In Heat Pumps: A Guide for Homeowners
Indeed we are invvestigating AC at present and are havi...
By Toodles , 3 days ago
-
RE: Daikin ESPAltherma and Home Assistant installation
It's laziness lol The PV system is very chatty, meter...
By bobflux , 4 days ago
-
RE: Problems with sizing a replacement for a Viessmann Vitocal 200-S
R (The R Project for Statistical Computing, I use it wi...
By cathodeRay , 4 days ago