If any of the main circuit is smaller than 28mm F/R you will get a fair bit of noise above 15 l/m, once the circuit has dropped off to a couple of emi...
@netdonkey excellent, I am glad I was thinking down the right track from the beginning, well done, the system really needs more flow than that, I woul...
@netdonkey yes you would have one in the condenser but its inside the cover and it would look something like that attached link. In your picture wh...
@netdonkey Sorry, one more thing, I note you say the system was installed in June 2024? if so, you are still well within your warranty and under HIES ...
@netdonkey I think if what you did just now made the system run for longer then it is air in the system and your flow may now have improved. As with...
@netdonkey Yes, the pump body is installed the correct way but the head (front of the pump is the wrong way), before the pump is installed it should h...
@netdonkey Reading the manual it looks like rotating the face is just to be able to read the interface, this instruction manual says to bleed to...
@netdonkey I am sorry to say, but I have just gone through the pictures again and although I cannot see the face of the pump I can clearly see the ...
@netdonkey We have a Evosta 3 set to fixed curve regulation mode level3. Is this correct? It looks like the Evosta has been installed upside dow...
@netdonkey I think you have an air lock, a restriction or for some reason a lack of flow.
@netdonkey Most 3 port valves dont look like they are all the way over but they are. You can ignore that lever for now. It looks like the arrows I ...
@transparent agreed. The labeling looks good.
- 26 Forums
- 2,364 Topics
- 53.6 K Posts
- 459 Online
- 6,029 Members
Join Us!
Worth Watching
Latest Posts
-
-
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
@kevh it's worth remembering that many lsvs only actual...
By JamesPa , 19 hours ago
-
RE: Setback savings - fact or fiction?
Exactly. We only need to compare conditions, to decide ...
By cathodeRay , 1 day ago
-
RE: Balancing financial efficiency and comfort using the Octopus Cosy tariff
I found because I have very low heat loss I can set bac...
By RadWhisperer , 1 day ago
-
RE: Need Help Optimising My Rushed ECO4 Install: 12kW Bosch Heat Pump
Welcome @mickamills We too have an oversized 12kW Sa...
By Old_Scientist , 1 day ago
-
RE: My Powerwall 3 Consumes 3-4 kWh/Day in Self-Consumption: Is This Normal?
@caron I can confirm that the power usage of the PW3 is...
By Old_Scientist , 1 day ago
-
RE: Speedcomfort radiator fans
Thats true, but having tried (and succeeded) in constru...
By JamesPa , 2 days ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash brilliant, thanks for the feedback
By energy9165 , 2 days ago
-
RE: Heat Pump Heats the House… But It’s Not Cosy. Emitter Changes or System Tweak?
@alastair There I was, feeling grumpy, he said “Cheer u...
By Toodles , 2 days ago
-
RE: Grant Aerona: Is there a setting to keep the 2-port valve open during pump blockade
Depends on OAT. Mine cycles at OAT>10 and of course...
By JamesPa , 2 days ago
-
RE: New Fogstar 15.5kWh upright solution
@transparent My conclusion is as you have noted, tha...
By Bash , 2 days ago
-
RE: Mitsubishi Ecodan R290 10kW performance
And to you too. Wishing you a very enjoyable festive s...
By Sheriff Fatman , 2 days ago
-
RE: External pipework insulation
They do? But that isn't apparent from the photos we'r...
By Transparent , 2 days ago
-
RE: Say hello and introduce yourself
@velcro welcome to the forums. Please feel free start a...
By Mars , 3 days ago
-
Daikin EDLA11D3V3 DHW Settings
I have a newly installed EDLA11D3V3 which I'm still get...
By Velcro , 3 days ago
-
RE: Midea ASHP – how to set weather compensation
@curlykatie did you get sorted with this?
By MickaMills , 3 days ago
-
RE: MyVaillant Connect Regular Disconnect
Thanks. Yes, if the time is consistently 11pm every nig...
By buckwem , 4 days ago