RE: Controller experiment - looking for volunteer(s)

@hcas - to find suitable test sites, I would recommend starting with a look at the various Community Energy groups across UK.That site has a UK map sh...

8 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Now that's interesting. I thought NICEIC only covered electrical portions of heat-pump installations.Thus, if the installer was accredited by NICEIC...

8 months ago
Reply
RE: Battery storage solution with ASHP

I should've added a smiley after my comment. There are a number of dominant criteria which affect how these future tariffs are constructed. 1: Pol...

8 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

The 'correct' glue to seal a split insulation like that is a contact adhesive like that from UHU. Once it's dried on each face of the split it can b...

8 months ago
Reply
RE: Battery storage solution with ASHP

The problem here is that we're trying to assess future financial viability whilst doing the maths on ToU tariffs which have been introduced recently, ...

8 months ago
Reply
RE: Air source heat pumps and noise

Interesting photo of that bracket @judith 😀 That looks to be the version of the Vaillant bracket for walls with external insulation.It use...

8 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

I also would NOT be temporarily re-sealing the pipe entry point after first inspecting what's been done. Instead, I'd screw a timber batten to the w...

8 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

IANAL but I think you removing material to inspect the way pipes pass through the wall is going to 'affect your case' either way. The installer is l...

8 months ago
Reply
RE: Battery storage solution with ASHP

@benson - I'd recommend that you check the functionality first, and the price afterwards. The GivEnergy product range is split into All-in-One ...

8 months ago
Reply
RE: The good, the bad and the not that great – my heat pump installation

Which way is up @burtis ? Is this a close up photo of the same two pipes we saw in your earlier photo? To pass pipes through a wall there must b...

8 months ago
Reply
RE: Air source heat pumps and noise

If I was going to make my own galvanised steel clamps to hold the feet in place,then I'd start with some roofing straps. There are two gauges.The ...

8 months ago
Reply
RE: Air source heat pumps and noise

Yes. If 400-450mm is adequate for the distance between the feet positions on your ASHP, then those are fine. Most people don't bolt them down..........

8 months ago