The Water Outlet temp on the controller screen will display the current flow temperature whether in space heating mode or during DHW heating, so durin...
The Legionella disinfection is done by the immersion heater, so normally it would not be responsible for the high flow temperature. When the heat pump...
@old_scientist I realise that the pump running 24/7 is now thought to be due to incorrect wiring and not the FSV settings. I just wanted to check that...
You may have a different model from me - mine is a Gen 6 12kW Samsung - but on mine there is no feedback from the controller on LWT when room temperat...
Running continuously will usually produce the best COP, but having setbacks where the pump is off for periods allowing the house to cool eg overnight ...
That seems odd and I have not seen or heard of that before. According to Midsummer Wholesale the Samsung controller is supposed to be a bit cleverer t...
HTC stands for Heat Transfer Coefficient - heat loss per C degree difference between IAT and OAT. It’s advantage is that it is independent of design t...
Delta T 20 implies that your desired room temperature would be 17.5C as the mean radiator temperature would be 37.5C at a flow temperature of 40C and ...
If you set it at 19C it will switch off at 19.9/20C and stay off until it drops to 18.9C. The 1C hysteresis cannot be changed. The alternative is to u...
@bontwoody Sorry for the lack of explanation. I was taking my comment from Glyn Hudson's recent observation on the OEM forum - "I found the onboard Sa...
@bontwoody I think the fact that your Samsung displays generated energy as less than OEM generated energy whereas mine is the reverse may just demonst...
@bontwoody That doesn't tally with my Samsung I'm afraid. For today, Samsung display's Generation/Usage = 3.05 compared to my Class 1 Electricity and ...
- 26 Forums
- 2,323 Topics
- 52.1 K Posts
- 240 Online
- 5,979 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Electricity price predictions
And therein lies the problem. A higher proportion of p...
By JamesPa , 25 minutes ago
-
RE: Solar panels on side of house to heat water
My solar panels (both PV and thermal) have not required...
By Transparent , 54 minutes ago
-
RE: A2A vs A2W: Which Heat Pump Would You Pick?
This would really be ideal and fans could also add to t...
By Batpred , 2 hours ago
-
RE: One Year Review: Grant 13kW ASHP - A Catalogue of Errors
@solenoid do you have the new smart controller or the o...
By Grantmethestrength , 3 hours ago
-
RE: Rate the quality of your heat pump design and installation
@solenoid Welcome. I have made some commen...
By JamesPa , 4 hours ago
-
RE: Mitsubishi Ecodan 11kw Defrosting Issue.
@f1p Thanks for the info, good to know
By ThunderMink , 6 hours ago
-
@toodles I will do, it can’t go any worse than my last ...
By Grantmethestrength , 20 hours ago
-
RE: Configuring third party dongle for Ecodan local control
Yes, it is certainly an advanced feature and quite diff...
By F1p , 21 hours ago
-
RE: MELcloud scheduling misbehaviour
@richard24738 We also want hot water for 7:00am showers...
By DavidAlgarve , 22 hours ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@hcas Thanks Henri. I take your point, but feel that wh...
By DavidAlgarve , 1 day ago
-
RE: Replacing my 18 month old Hitachi Yutaki ASHP
The Thermo Off (not Thermal Off) only relates to the la...
By trebor12345 , 1 day ago
-
RE: Flow rate discrepancy between ASHP and manifold
Ok, I think I have got to the bottom of the problem... ...
By AshRolls , 1 day ago
-
RE: British Gas vs Octopus Energy vs Heat Geek vs EDF vs Aira vs OVO vs EON.Next vs Boxt
@editor OVO: 'Sorry, we aren't installing heat pumps in...
By stevettweed , 1 day ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
@bash — I also agree, an image based installation is th...
By cathodeRay , 1 day ago
-
RE: Signenergy AI Mode - How long does it take to learn a usage pattern?
@grantmethestrength What I mentioned is just out of ...
By Batpred , 1 day ago
-
RE: Testing new controls/monitoring for Midea Clone ASHP
Very true, that is the standard method (and the one I u...
By cathodeRay , 1 day ago
-
RE: Our journey through Octopus tariffs 2020-2025
@tim441 guess "every little helps". I plan to let Sol...
By Batpred , 2 days ago
-
RE: Why Millions of UK Homes Struggle With Heat Pumps
If it is combined with the BUS and they make it all goo...
By Batpred , 2 days ago
-
RE: Advice on reading thermal images
@editor Thanks Mars, better price from the website and ...
By colinc , 2 days ago