@editor Mars, thank you. That's along the routes I was thinking. I had considered reaching out to companies advertising system design engineers but th...
@jamespa @transparent, Thank you both! What do you mean by an extra active component? Surely it's the same, just the location of the heat exchanger...
@transparent thank you! I was planning to turn it down from 55 myself and monitor the daily changeover so I could work out how best to minimise...
@old_scientist Thank you! Right, so I shouldn't consider the manufacturers stated or estimated values when comparing my quotes, they're basically all ...
@judith thanks! I think Eon basically haven't bothered to work out then DHW COP for any pump or design presented, which is slightly concerning... Howe...
@jamespa yes I think I've downloaded half hourly from Octopus, I think they gave it in gas m3 though... I can't be certain of the exact schedule as ...
@jamespa I have approx 20 months of gas energy usage. DHW usage is limited, occasional washing up, baby/toddler baths and occasionally showers. We had...
@sicky 72m2 for the whole downstairs, it was very much a rough guestimate on price when I asked about other options instead of rads.
@jamespa yes thanks, I've been quoted a min SCOP of 3.60, so as long as I could get cheaper electric than 22p I think it starts to pay it back. Anothe...
@jamespa I had one company design at 55 because I was struggling for radiator space... I've had others pull out because I couldn't heat the room prope...
- 22 Forums
- 2,036 Topics
- 44.4 K Posts
- 23 Online
- 3,240 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
RE: The Rise and Fall of Europe’s Most Generous Green Subsidy
@dwynwen welcome back… and glad to hear you made it thr...
By Mars , 10 hours ago
-
RE: Air Source Heat Pump - Side Alley Suitability
@ad3628 I’ve seen loads of heat pumps successfully inst...
By Mars , 10 hours ago
-
RE: Hitachi Yutaki SCombi Heat Pump - Thermal Off's
@trebor12345 The Auto function is supposed to adapt au...
By Heatgeek , 12 hours ago
-
RE: In the middle of an ASHP installation - a few questions (and issues)
@jamespa they didn't provide any contract, or design pr...
By benson , 15 hours ago
-
RE: The Great British Heat Pump Quiz
@allyfish thanks for the feedback and glad it was fun! ...
By Mars , 17 hours ago
-
RE: help sizing rads based on room by room heat loss
If its 1988W at DT 50, which is how most radiators are ...
By JamesPa , 22 hours ago
-
RE: Career change – entering the world of heating and heat pumps
@editor Mars, thank you. That's along the routes I was ...
By Lakey , 22 hours ago
-
@editor thanks Mars, it's a rare occasion I'm looking f...
By big_si , 1 day ago
-
RE: Efficiency Concerns on newly installed Mitsubishi Ecodan 8.5kW
@ashp-bobba and @jamespa - thank you both for all your ...
By CBrenewable , 1 day ago
-
-
Win one of five "Heat Pumps 101" Courses
Heat pumps are gaining traction in the UK, but between ...
By Mars , 2 days ago
-
RE: Agile: average import cost vs other tariffs?
@toodles thanks for the analysis. I'll be really intere...
By Old_Scientist , 2 days ago
-
RE: ASHP Ecodan L9 error - No Heating but Hot Water
@phoenix15 I'm no plumber so please don't take this as ...
By dnagre , 2 days ago
-
RE: Is this normal? Click of the DHW returning to space heating
@grantmethestrength Oh sorry to hear that, there should...
By ASHP-BOBBA , 3 days ago
-
@ashp-bobba TBH the ladies are rather disorganised, so ...
By Cathyem1 , 3 days ago
-
RE: Solar Power Output – Let’s Compare Generation Figures
And for those of us without an automatic irrigation sys...
By Majordennisbloodnok , 3 days ago
-
Logically, the lower frequency = more gentle, yes, but ...
By SUNandAIR , 3 days ago
-
RE: Ideal Logic ASHP - change from 55°C to 35°C Heating?
Good point. I’ll keep my eye on the manifold temperatur...
By Tomdad , 3 days ago
-
RE: How hard and expensive would it be to change panel and add battery?
@transparent It is a setting that Octopus make via the ...
By Toodles , 3 days ago