Last seen: Jan 8, 2025
@damijand sorry, then I don't know why room temp isn't displayed. I'll ask on another group I'm on and let you know.
You may have to change the sensor settings in Initial Settings. I'm not at home so I can't check mine to see which it needs to be. I think you need ...
The ones that can deliver what it says on the badge when it's cold outside will be able to deliver more under the right conditions. A 14kW Ecodan wil...
A Samsung HHSM- G600016-1 won't produce anything like 16.6kW at -3. The link below suggests more like 12-14kW at these low temperatures. You s...
@damijand the PAC-SE41TS-E is the one I meant. Although it's wired it comes with a long cable. If you want wireless, you'll need a PAR-WR51R-E and...
Love them or hate them, we need companies like BG (and Octopus) involved to move ASHPs into the mass market. It is interesting that if not wholeheart...
I don't know why an oversized ASHP would mess up Melcloud reporting. I think the Melcloud consumption is measured; it's the delivered that's estimate...
What you also need to remember is that when the heating is off, all the fixed overheads of keeping the ASHP on standby, running the controllers and al...
I'm assuming you don't have a hot tub or swimming pool or EV you haven't mentioned and it is the case that your AHSP is using most of the 14,000 kWh. ...
Just over 2 for me too but that's for a whole year. Ecodan with new 250l tank.
Based on mine, I suspect your losses from the HW tank are as expected. It's not going to cost much; mine costs less than 2kWh per day to maintain tem...
@westkent It will lose heat through the tank insulation as well as the pipes. The pipes will make a small but significant difference. Your tank i...
- 26 Forums
- 2,275 Topics
- 50.9 K Posts
- 281 Online
- 5,936 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Testing new controls/monitoring for Midea Clone ASHP
It has it's uses and there is no way I could have set t...
By benson , 2 hours ago
-
Samsung Gen6 and Havenwise ........
I sourced the Wi-Fi unit (City Plumbing - £122 with 15%...
By Lenny , 2 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Definitely. 8C DT is higher than the default design DT...
By JamesPa , 4 hours ago
-
@jamespa Thanks again for your reassurance. Rob
By Ubert767 , 9 hours ago
-
RE: Oil Boiler & Heat Pump Hybrid System
Thanks for the suggestion, but farmhouse is grade 2 lis...
By paultheheating , 11 hours ago
-
RE: My DIY Heat Pump installation
This is very kind. However software is not really my ...
By Polar bear , 16 hours ago
-
RE: Request for feedback on where we're at with our quest to get an ASHP or ideas.
thanks, heatpunk looks great, being able to do the calc...
By giryan , 1 day ago
-
RE: Is Your House Warmer Upstairs Than Downstairs?
Why arent you expecting them to make much difference. ...
By JamesPa , 1 day ago
-
@toodles sounds good. I started with cosy but then plug...
By Eliuccio , 1 day ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
It has been just over a year since we changed over to a...
By npru , 1 day ago
-
RE: Finding a Thermostatic Shower Valve That Works with Heat Pump Systems
@morgan I should just have written ‘Mea Culpa’ shouldn’...
By Toodles , 1 day ago
-
RE: Are We Sleepwalking Into Another Race to the Bottom?
'We learn from history that we do not learn from histor...
By Lawrence Leask FInstR , 1 day ago
-
Mitsubishi Ecodan FTC7 Legionella date set
I can set the number of days between Legionella cycles ...
By DRB01 , 2 days ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
@treewizard Yes, I like the extra facilities that NetZe...
By Toodles , 2 days ago
-
RE: Help me keep the faith with my air source heat pump installation
@adamk downstairs rads are less prone to airlocks, you ...
By AgentGeorge , 2 days ago
-
RE: My Octopus Cosy 6 Heat Pump Journey: From Quote to Completion
@editor thanks for highlighting my name. Yes I did get ...
By Chansug , 2 days ago
-
RE: balancing radiators with a mixture of different size pipework and a few undersize rads.
@editor Thanks for your input Mars. No I think the comm...
By baxtDave , 2 days ago
-
RE: Rate the quality of your heat pump design and installation
We’re looking to expand our list of recommended list of...
By Mars , 2 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@transparent Along with the right workers, they can’t b...
By Toodles , 3 days ago