Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

JamesPa
JamesPa
@jamespa
Moderator
Illustrious Member
Joined: Apr 3, 2023
Last seen: Aug 13, 2026
Topics: 27 / Replies: 5232
Reply
RE: Odd noise in our Ideal Logic ASHP

I love (and will use) that analogy!

10 months ago
Reply
RE: Low COP and unevenly heated rooms with 12kW Samsung AE120MXTPEH / AE260TNWTEH

Where is the noise coming from. If its the pump then perhaps somehow put some insulation around the pump. If its the rads, is it the valves. or the ...

10 months ago
Reply
RE: Automation options to maximuse efficiency & ToU tariffs

If you are asking what is available to the non geek householder to optimise for ToU tarrifs, its Homely, Havenwise or Adia. To the best of my knowled...

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Yes. I expect Grant specify a 'minimum system volume' which is the minimum permitted engaged (ie open) volume including the volumiser. Most manufact...

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Which is logical, albeit 30l is a bit small. The manual it seems is clear which trumps anything the installer says and TBH anything the grant helpli...

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Volumiser totally different to buffer or llh. Volumiser 2 ports, buffer/llh 4, volumiser doesn't cause system distortion, doesn't penalise COP, buffe...

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

R290 has an explicit installer setting for 'no buffer'. It couldn't be clearer!  

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

They arent one offs, but they will empty the system in part if they go off. Better than making it work less well by filling with Glycol. Some argue ...

10 months ago
Reply
RE: Odd noise in our Ideal Logic ASHP

These are well respected pumps so far as I know. Only one radiator on sounds very wrong, this should never be allowed to happen and is almost bound...

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

He is right. Better to eliminate it altogether. Is the Grant the R290 or the R32? The instructions for the R290 (which as it happens I was reading ...

10 months ago
Reply
RE: Grant 13kW Aerona3 - issues getting zones to temp

Sorry but the more I think about this the more its shouting RED FLAG. The work is, you say going to be done in a day. He is probably going to fit a ...

10 months ago
Reply
RE: Should Our Water Circulation Pump Be Configured to Run All The Time?

Noted The Vaillant doesn't either, other than with a board swap. A bit mad TBH.  