Reply
RE: Installing your own ASHP - DIY

@tomasmcguinness Have you been able to perform any sanity check on that figure? I'm thinking of the 'divide annual gas consumption by 2900' rule of t...

6 days ago
Reply
RE: Microbore Central Heating Plumbing, will it be a barrier / pain?

@mattc All the existing (designed for T50) radiators are single panel, only around half with fins. I think the system was probably well designed when ...

6 days ago
Reply
RE: Microbore Central Heating Plumbing, will it be a barrier / pain?

I have 10mm copper microbore installed behind dot & dab plasterboard for the downstairs radiators. I’ve done my heat loss survey and have conclude...

7 days ago
Reply
RE: Aira Heat Pump: Stylish Scandinavian Heating

That's why I didn't go for a Tado controller for my boiler control 7 or 8 years ago. Instead, I went with a Drayton miGenie internet-enabled controll...

1 week ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

@derek-m - The electricity supply industry relies on 'diversity' with regard to phase balancing and hopes for a reasonable balance of loads across t...

2 weeks ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

Here is NGED's policy document: NGED Standardisation of Fusing to 80A My 100A service head was replaced with an 80A one last year after I rashly rep...

2 weeks ago
Reply
RE: EV charger installation question – I don't want to bury the cable

@transparent If it's a Podpoint Solo EV charger, a quick look at the installation guide suggests it has has a form of PEN fault detection and can be...

2 weeks ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

At present, the focus of many people - I'm thinking of PV and domestic battery owners here - is on export limitation to the grid. (Call me a cynic, b...

2 weeks ago
Reply
RE: EV charger installation question – I don't want to bury the cable

@hem Depending on the charger you install, an option may be to use an SWA cable with an integral cat5 cable. This may be used either for an intern...

2 weeks ago
Reply
RE: MCS Heat Loss Calculations

I don't know about 'rules'; I did my calculations by first principles, considering where any heat would be lost. Basically, first floor ceiling losse...

2 weeks ago
Reply
RE: Octopus (the grid) is my battery

I've just looked back on my bill for 15 Feb - 8 March and I was charged 14.05p/kWh +VAT. I can't understand these people who insist they won't have a...

4 weeks ago