Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 29, 2025
@jamespa Yes, you are right, I was misreading the diagram. ☹ The main point that I was trying to make, however, is that the heat has to be carr...
@jamespa Apologies. My last post was made before I read your response. The answer is in your own diagram. Resultant internal DT is points 3 to 4 ...
@declan90 Answer is, yes. Power set for a rad is the Flow x DT x SH-of-Water. So if you adjust the flow down, you will have to adjust DT upwards to ...
@jamespa One can only consider the whole system. The DT is a consequence of the emitters connected to the HP. I agree that COP is determined not only ...
@declan90 I have some hopefully interesting input for you if you don’t think it is bollocks. Your statement about adjusting your pump for 5C dT got me...
I was previously under the impression that the Vaillant had a Grundfos UPM2 pump which is an externally cable controlled OEM version but was puzzled b...
@declan90 Thanks for this. I see where you are coming from. I don’t agree that what you are doing by increasing dT will reduce your COP. It’s opposite...
@jamespa Agree entirely.
I have no idea.
The 4kW unit can modulate down to 1.5kW or just below 5 l/min @ 5C dT. However, the flow switch will throw a E911 low flow alarm if you try and go bel...
@jamespa Hi. Information as requested. 1. Samsung Split Gen 4 with Grundfos UPM3 PWM pump integrated in the internal unit with PHE, running for 10...
Apologies for the delay in response due to other heated issues (pardon the pun).😊 Oh boy, why is this so hard? I am not mistaking modulation ...
- 26 Forums
- 2,717 Topics
- 63.6 K Posts
- 3,457 Online
- 7,119 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: New Vaillant aroTherm Plus in black - When will it come to the UK?
It’s here
By avenir , 7 minutes ago
-
Hi everyone, I’m looking for real-world advice and co...
By asoksevil , 3 hours ago
-
I knew that Reactive Power support was required by the ...
By Transparent , 4 hours ago
-
RE: Indevolt Batteries UK Support & Info Thread
Those are very good questions and indeed ones I was ask...
By JamesPa , 7 hours ago
-
For cooling a whole building, or even a big room with l...
By EtchedPixels , 8 hours ago
-
RE: Comms and power cabling to outside unit
@old_scientist 100%, the cover is for warrantied unit...
By Papahuhu , 8 hours ago
-
I don't remember the manufacturer name, but I saw simil...
By bobflux , 10 hours ago
-
RE: Weather compensated secondary circuits with Biomass
UFH is ideal to get max efficiency with a heat pump, bu...
By bobflux , 10 hours ago
-
RE: Vaillant Arotherm Pro vs new Plus
when our system was installed in September 2 years ago ...
By Judith , 1 day ago
-
RE: Rate the quality of your heat pump design and installation
I had a Heat Geek lead install by Green Heat Norfolk. T...
By Orlando , 1 day ago
-
RE: Mitsubishi Ecodan FTC6 settings
While @F1p's dongles are great, the FTC can do this its...
By RobS , 2 days ago
-
RE: Samsung heat pump - data cable issue
If it's a data cable, current will be minuscule, voltag...
By bobflux , 2 days ago
-
RE: MCS Quality Audit – Has Anyone Had One? Did It Lead to Remediation?
I got hit with an RHI audit in 2022. It was far from c...
By Abernyte , 2 days ago
-
Hi,is there any Haier super aqua gt users on here,that ...
By Glenn Crawford , 2 days ago
-
RE: Electricity price predictions
@papahuhu Groucho Marx had something to say about no...
By Toodles , 2 days ago