Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Heatgeek
@heatgeek
Member
Estimable Member
Joined: Dec 16, 2024
Last seen: May 29, 2025
Topics: 1 / Replies: 116
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

@jamespa Yes, you are right, I was misreading the diagram. ☹ The main point that I was trying to make, however, is that the heat has to be carr...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

@jamespa Apologies. My last post was made before I read your response. The answer is in your own diagram. Resultant internal DT is points 3 to 4 ...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

@declan90 Answer is, yes. Power set for a rad is the Flow x DT x SH-of-Water. So if you adjust the flow down, you will have to adjust DT upwards to ...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

@jamespa One can only consider the whole system. The DT is a consequence of the emitters connected to the HP. I agree that COP is determined not only ...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

@declan90 I have some hopefully interesting input for you if you don’t think it is bollocks. Your statement about adjusting your pump for 5C dT got me...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

I was previously under the impression that the Vaillant had a Grundfos UPM2 pump which is an externally cable controlled OEM version but was puzzled b...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

@declan90 Thanks for this. I see where you are coming from. I don’t agree that what you are doing by increasing dT will reduce your COP. It’s opposite...

1 year ago
Reply
RE: (How) does your heat pump control its water pump?

The 4kW unit can modulate down to 1.5kW or just below 5 l/min @ 5C dT. However, the flow switch will throw a E911 low flow alarm if you try and go bel...

1 year ago
Reply
RE: (How) does your heat pump control its water pump?

@jamespa Hi. Information as requested. 1. Samsung Split Gen 4 with Grundfos UPM3 PWM pump integrated in the internal unit with PHE, running for 10...

1 year ago
Reply
RE: Anyone able to provide some feedback before I make my finale decision? Samsung vs Baxi vs Vaillant

Apologies for the delay in response due to other heated issues (pardon the pun).😊 Oh boy, why is this so hard? I am not mistaking modulation ...