Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: May 29, 2025
@jamespa Yes, you are right, I was misreading the diagram. ☹ The main point that I was trying to make, however, is that the heat has to be carr...
@jamespa Apologies. My last post was made before I read your response. The answer is in your own diagram. Resultant internal DT is points 3 to 4 ...
@declan90 Answer is, yes. Power set for a rad is the Flow x DT x SH-of-Water. So if you adjust the flow down, you will have to adjust DT upwards to ...
@jamespa One can only consider the whole system. The DT is a consequence of the emitters connected to the HP. I agree that COP is determined not only ...
@declan90 I have some hopefully interesting input for you if you don’t think it is bollocks. Your statement about adjusting your pump for 5C dT got me...
I was previously under the impression that the Vaillant had a Grundfos UPM2 pump which is an externally cable controlled OEM version but was puzzled b...
@declan90 Thanks for this. I see where you are coming from. I don’t agree that what you are doing by increasing dT will reduce your COP. It’s opposite...
@jamespa Agree entirely.
I have no idea.
The 4kW unit can modulate down to 1.5kW or just below 5 l/min @ 5C dT. However, the flow switch will throw a E911 low flow alarm if you try and go bel...
@jamespa Hi. Information as requested. 1. Samsung Split Gen 4 with Grundfos UPM3 PWM pump integrated in the internal unit with PHE, running for 10...
Apologies for the delay in response due to other heated issues (pardon the pun).😊 Oh boy, why is this so hard? I am not mistaking modulation ...
- 27 Forums
- 2,808 Topics
- 66.3 K Posts
- 2,464 Online
- 7,212 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: The Changing Jet Stream Could Challenge UK Air Source Heat Pumps
@susannasaunders I use the A2A for shoulder periods ...
By Watcher , 10 hours ago
-
RE: Marvel Heating liquidation
The interesting thing about the IBG: when I called them...
By davidnolan22 , 13 hours ago
-
Boiler Upgrade Scheme funding reduced by circa £750 million in 2026 budget
The funding for the BUS grant appears to have been subj...
By Rob of York , 20 hours ago
-
RE: Vaillant ecoTEC Plus - Flow Temp and Set Up
JamesPa The chart explains well how the heat curve an...
By trebor12345 , 24 hours ago
-
RE: Free app: run the immersion / heat pump from Growatt battery & solar surplus – no Home Assistant
Please bear in mind, everyone, that in order to use thi...
By Majordennisbloodnok , 2 days ago
-
RE: The good, the bad and the not that great – my heat pump installation
@burtis Thanks for posting this and Im so pleased you ...
By JamesPa , 2 days ago
-
RE: I need help with Ecodan ASHP
@f1p It turns out there have been a solar panel install...
By Andris , 3 days ago
-
RE: 15kw pump for 225m2 1990's house - over kill?
@seaviews your installer would be right to say that the...
By GrahamF , 3 days ago
-
RE: Tradespeople on Their Phones: What’s Acceptable When They’re Working in Your Home?
Actually, that's a very important point. I've only ev...
By Majordennisbloodnok , 3 days ago
-
RE: Aerotherm and weather compensation
These are likely inked. The basic explanation is tha...
By JamesPa , 3 days ago
-
RE: Electrical works for air to air heat pump
agree with above. I have not had extra costs added wh...
By Batpred , 3 days ago
-
Good to hear that you found a solution. Absolutely a...
By Batpred , 3 days ago
-
RE: Are there any comparisons of DHW heat stores around?
@sarahemmm I have done things the opposite way round I ...
By Toodles , 4 days ago
-
RE: How will removing the standing charge on gas bills benefit heat pumps?
The BUS grant funding for 2026/27 will run out at the c...
By Rob of York , 5 days ago