Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!

Damon Blakemore
@damon
Member Professional Installer
Eminent Member
Joined: Mar 24, 2024
Last seen: Feb 8, 2026
Topics: 0 / Replies: 17
Reply
RE: Kronoterm Versi-i loft sited heat pump installs

@editor I haven’t installed a Kronoterm yet, last year was a heliotherm.   i have a Versi I’m installing later this year along with an adapt...

1 month ago
Reply
RE: Which 6kw to 8kw ASHP can modulate down the lowest ?

@editor the easiest way to find out is to look at the data on open energy monitor. we seem to have a fascination now with low end mod which good con...

4 months ago
Reply
RE: Mixergy Tank Failure

Firstly if your not g3 qualified then I wouldn’t touch it.   Mixergy can’t tell you what pressure to set the expansion vessel at as they don’...

6 months ago
Reply
RE: Heat pump solutions and/or installer recommendations for France

I’d travel to France for work if you were struggling with finding anyone.

8 months ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

The 16kw will only give you 12kw around 0° so be careful when looking to have that fitted. But you will only have around 15kpa left for the system ...

10 months ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

@jamespa so I fit Nibe, Viessmann, Vaillant, Grant and Heliotherm. I also fitted a new Worcester the other week but that was a favour. id...

10 months ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

@heatgeek Nibe also promote the two pipe buffer, I use this set up when cascading. you would want flow rates matching best you could though. Alt...

10 months ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

@heatgeek this is for an additional buffer vessel, used for separation. it can prolong run times but imo you would be better with a volumiser ra...

10 months ago
Reply
RE: Heat Pump Manufacturers Recommending Buffer Tanks

@editor it’s a defrost buffer, it uses an Esbe 4 way valve in a three way configuration, hot water, buffer, heating. when it senses it requires a ...

10 months ago
Reply
RE: Large ASHP recommendations for listed house

The first issue you have is the dated m&e consultants. Everything is copy and paste and old school workings. you need someone who deals with de...

1 year ago
Reply
RE: Large ASHP recommendations for listed house

Firstly by being “suggested” what does this mean? has a full heatloss survey been carrie don’t determine what load is required? by periodic i...

1 year ago
Reply
RE: Installing a heat pump in a Grade II listed property

What is that base?? The isolator looks like it’s in the restrictive zone. The diverter valve has a very low value and shut off pressure for a ...

1 year ago