Last seen: Oct 11, 2025
Firstly if your not g3 qualified then I wouldn’t touch it. Mixergy can’t tell you what pressure to set the expansion vessel at as they don’...
I’d travel to France for work if you were struggling with finding anyone.
The 16kw will only give you 12kw around 0° so be careful when looking to have that fitted. But you will only have around 15kpa left for the system ...
@jamespa so I fit Nibe, Viessmann, Vaillant, Grant and Heliotherm. I also fitted a new Worcester the other week but that was a favour. id...
@heatgeek Nibe also promote the two pipe buffer, I use this set up when cascading. you would want flow rates matching best you could though. Alt...
@heatgeek this is for an additional buffer vessel, used for separation. it can prolong run times but imo you would be better with a volumiser ra...
@editor it’s a defrost buffer, it uses an Esbe 4 way valve in a three way configuration, hot water, buffer, heating. when it senses it requires a ...
The first issue you have is the dated m&e consultants. Everything is copy and paste and old school workings. you need someone who deals with de...
Firstly by being “suggested” what does this mean? has a full heatloss survey been carrie don’t determine what load is required? by periodic i...
What is that base?? The isolator looks like it’s in the restrictive zone. The diverter valve has a very low value and shut off pressure for a ...
Sorry about the wind and the Evian! There is a buffer yes but it's got a unique feature. Its a defrost buffer not a buffer we would use for hyd...
I do provide heatloss and design packages separate in all my own sort I love installing but the design side is where I find myself more drawn. in my...
- 26 Forums
- 2,238 Topics
- 49.8 K Posts
- 192 Online
- 5,900 Members
Join Us!
Podcast Picks
Latest Posts
-
This is the User Manual for the Ecodan to MelCloud inte...
By DavidAlgarve , 2 minutes ago
-
@springswood we install these nationwide and I have the...
By dgclimatecontrol , 3 minutes ago
-
Daikin Altherma 3M ASHP and British Gas Hive Home
In August 2024, we went all electric had a new Daikin D...
By weoleyric , 33 minutes ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
The cycling suggests that there may be scope to reduce ...
By JamesPa , 36 minutes ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
Just returning to this issue after a few days working i...
By Mike Patrick , 2 hours ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
I wholeheartedly agree with everything @allyfish has wr...
By Old_Scientist , 3 hours ago
-
RE: Renewables & Heat Pumps in the News
Back again to the Spanish blackout this was in the E...
By Judith , 3 hours ago
-
RE: DESNZ doing a survey which asks the right questions!
Fair comment. I have a feeling that ratings more gen...
By JamesPa , 6 hours ago
-
RE: Daikin Octopus installation update - I saw my first defrost. 😍😂
@jancold Not a plumber but I believe that i...
By RadWhisperer , 6 hours ago
-
Thanks! My consumer unit collection is ready with the W...
By Batpred , 9 hours ago
-
RE: Solar inverters - where does the energy go when clipping?
Since the combination of fitting plus scaffolding makes...
By Judith , 17 hours ago
-
RE: Designing my house system with a mix of air to air and air to water
@jamespa Cheers James, it's great reading. In quite a f...
By pipebaron , 18 hours ago
-
RE: PV Panels on roof in Conservation Area
If there is any way you can determine daily oil consump...
By JamesPa , 18 hours ago
-
RE: My experience with 3 heat pump surveys: Heat Geek, British Gas & Octopus
Good plan and pretty much what I did in the end (there ...
By JamesPa , 19 hours ago
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
attached is prelagged in case indicates anything. &nb...
By Crimson , 21 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Via the cloud and via the online, similar data is shown...
By Batpred , 1 day ago
-
@old_scientist yes. No E911 error. Very odd. Thanks for...
By bontwoody , 1 day ago
-
RE: Incorrect Billing of Customers with a Smart Meter
How odd @korwraith - that functionality being offered ...
By Transparent , 1 day ago
-
RE: Master & Slave Zones/Setback
Re outdoor probes can be added from the ones attached t...
By bretix , 1 day ago
-
RE: Octopus Cosy & Octopus EV + bidirectional smart tariff, together. What, eh?
Thanks for sharing this, it is clearly disappointing, B...
By Batpred , 2 days ago