Last seen: Jun 20, 2025
1. Is the power supply genuinely capable of delivering 10A? Or is it possibly a broad allusion to 10A, based on the rating of the components used insi...
I wonder if I should change my advice on top-balancing. Should I recommend connecting the cells to the power-supply via an external/visible fuse? ...
No... you're not an idiot. You did exactly the right thing by posting here. We need to keep the above dialogue intact here so that future DIY instal...
On your earlier photos you had the flat-plate copper busbars connecting to the positive terminals of the cells, which were closest to the front edge o...
You require Constant Voltage mode. You're bringing all cells up to the same 3.6v (or whatever you choose). Use a multimeter to see what's actually b...
Low voltage and high current is typically a short-circuit. Have you got one or more of the cells reversed? The positive terminals should all be conn...
It's meant to the other way around. Levelling Up is a policy which must be adhered to throughout all aspects of Government action: From the Levellin...
Valid point. Levelling Up is Government Policy. I have already alerted my MP to another aspect of Levelling Up which has been ignored/overlooked by ...
I'm not sure that is a statutory requirement. When I installed my thermal store in a renovation project in 2005, Part L1b of the Building Regulation...
Welcome to the forum @tommyt11 I don't think that the Mixergy tank has been described here before. I'm aware of it because of discussions on another...
If I were trying to identify those who might not have concerns about electricity & gas being consumed for luxury, then I'd include most MPs and di...
That's good @batalto The first step is to first decide on what voltage you are going to use as the upper limit. This will typically be just above 3....
- 22 Forums
- 2,084 Topics
- 46 K Posts
- 17 Online
- 3,377 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
@judith good to know… I’ll continue to feed Wattson, an...
By Mars , 6 hours ago
-
RE: Vaillant AroTherm Plus 7kW
@jamespa I have a hydronic baseboard heater in the kitc...
By Scalextrix , 12 hours ago
-
RE: Getting the best out of a heat pump - is Homely a possible answer?
I think that QR code is to download the app SmartHome o...
By cathodeRay , 18 hours ago
-
RE: My misgivings about installing ASHP and solar panels via the ECO4 scheme...
@editor great article re accreditation. I note ISO/IEC ...
By Bart , 21 hours ago
-
RE: Renewables & Heat Pumps in the News
Here’s a little more technical detail/p>
By Judith , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
I don't (yet), but my PW3 is due to be installed shortl...
By Old_Scientist , 2 days ago
-
RE: MCS and NAPIT complaints process
@chrislay, is your heat pump complaint still unresolved...
By Mars , 2 days ago
-
RE: ASHP Install from hell - help please
@saf1973 I’ve been going through old cases on the forum...
By Mars , 2 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@aaron There's the rub, the database does not list my ...
By AF1 , 2 days ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
@editor excellent news, congratulations and well deserv...
By ASHP-BOBBA , 2 days ago
-
RE: Commencing on an ASHP Installation Process
Yes, it's "doable" if everything goes to plan, they arr...
By Old_Scientist , 4 days ago
-
RE: How not to install a heat pump
You are right. Thinking on this has evolved over the p...
By JamesPa , 4 days ago
-
RE: DHW SET UP with Samsung gen 5
Thats good news indeed, you are very likely almost ther...
By JamesPa , 4 days ago
-
RE: Plate heat exchanger considerations
As far as I can tell my vented system would have a peak...
By Scalextrix , 5 days ago
-
RE: Air Changes per Hour - ACH and the MCS requirement
There have been a few discussions dotted around (e.g. I...
By Declan90 , 5 days ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
Having made some enquiries locally I have found a compa...
By Morgan , 5 days ago