Yes, tiles are good conductors. 🙂 Do you know if the concrete pads have a thermal break (of insulation) in the rooms where they abut an external wa...
I'm not sure that the floor area of the room is the most significant factor. The mass of the concrete pad, the floor surface which covers it and the...
It's not common to have any manual adjustment on an UFH manifold like that. Don't start unscrewing red rings unless you are completely certain of wh...
Thanks. So I can see the white mains-powered thermal actuators on the lower (flow) level of the manifolds, and the flow-gauges on the return side. ...
Yes, it will certainly interfere! Every room requires its own stat/timer. If your manifold allows the flow-rate to be changed, then by all means d...
Since the actuators are effectively 'digital', the bathroom will take its heat first because the resistance is lower. But, of course, its thermostat...
On a related note, I'm currently installing several BMS units from different manufacturers. The Chinese ones have optional colour LCD touch screens,...
It depends in which clearance-sale you trawl for bargains. 😉 I paid £11 because the wholesaler was going to be stocking a rival to Alpha-wire in fu...
Yes. If you've only got one RS485 port on the end of the cable, then you won't need a terminating resistor. I'm currently experimenting using a scre...
Yes of course I'll share what results I get.But as I said, I've only just imported these modules. They're still sat on the workbench, not connected to...
If you want to place a few temperature or voltage sensors around your heat-pump, you could consider using an analogue acquisition module with a Modbus...
Oh great - more hardware questions. 😀 FTP is well beyond the cable spec you're after. But it'll do ok.Let's remember that RS485 gets deployed in re...
- 22 Forums
- 2,084 Topics
- 46 K Posts
- 50 Online
- 3,377 Members
Join Us!
Trusted Installers
Struggling to find a reliable heat pump installer? A poor installation can lead to inefficiencies and high running costs. We now connect homeowners with top-rated installers who deliver quality work and excellent service.
✅ Verified, trusted & experienced installers
✅ Nationwide coverage expanding
✅ Special offers available
Latest Posts
-
RE: Surface mount or bury primaries for heat pump installation?
@tomasmcguinness bold choice on the Kronoterm. Nice! Wi...
By Mars , 3 hours ago
-
RE: Getting the best out of a heat pump - is Homely a possible answer?
It took me more than a few goes as well, plus some help...
By cathodeRay , 19 hours ago
-
RE: Renewable Heating Hub Homeowners' Q&A Podcast
@ashp-bobba thank you, and equally so, thank you for ta...
By Mars , 1 day ago
-
@judith good to know… I’ll continue to feed Wattson, an...
By Mars , 2 days ago
-
RE: Vaillant AroTherm Plus 7kW
@jamespa I have a hydronic baseboard heater in the kitc...
By Scalextrix , 2 days ago
-
RE: My misgivings about installing ASHP and solar panels via the ECO4 scheme...
@editor great article re accreditation. I note ISO/IEC ...
By Bart , 2 days ago
-
RE: Renewables & Heat Pumps in the News
Here’s a little more technical detail/p>
By Judith , 3 days ago
-
RE: Who's your electricity provider and what's your tariff?
I don't (yet), but my PW3 is due to be installed shortl...
By Old_Scientist , 3 days ago
-
RE: MCS and NAPIT complaints process
@chrislay, is your heat pump complaint still unresolved...
By Mars , 3 days ago
-
RE: ASHP Install from hell - help please
@saf1973 I’ve been going through old cases on the forum...
By Mars , 3 days ago
-
RE: RDSAP10 effect on existing heat pump EPC rating?
@aaron There's the rub, the database does not list my ...
By AF1 , 4 days ago
-
RE: Commencing on an ASHP Installation Process
Yes, it's "doable" if everything goes to plan, they arr...
By Old_Scientist , 5 days ago
-
RE: How not to install a heat pump
You are right. Thinking on this has evolved over the p...
By JamesPa , 6 days ago
-
RE: DHW SET UP with Samsung gen 5
Thats good news indeed, you are very likely almost ther...
By JamesPa , 6 days ago
-
RE: Plate heat exchanger considerations
As far as I can tell my vented system would have a peak...
By Scalextrix , 6 days ago
-
RE: Air Changes per Hour - ACH and the MCS requirement
There have been a few discussions dotted around (e.g. I...
By Declan90 , 6 days ago