This is an interesting one which had faintly crossed my mind. Does any heat pump do this. I have heard that there are some which have an auxiliary...
I will concede that the first sentence was blunt and for that I apologise if offence was caused. It was intended to be succinct (surely a good thing)...
Thats a brilliant plot with a full range of temperatures. Your 'no cycle' window is clearly shown as about 8C-5C. The cycles even only just above 8C...
I 100% agree that this needs tackling and understanding. I have seen very little analysis of the economics of part time heating with either fossil f...
In fairness that is well understood and why its costs over a season/SCOP that commonly get quoted and compared not costs at any particular temperature...
⁶ The article goes on to say this "However, minimum standards for energy efficiency in newly built properties under the rules will preclude th...
I can see the magnaclean. I cant remember whats inside TBH but that sounds about right. Oh dear - its just possible that the heat exchanger coul...
as @downfield says fan radiators (with the exception, I think, of the Myson Ulow-2 which is literally a more or less standard radiator plus fans) have...
All noted, I hadn't encountered HTC before, but now you have explained it it makes perfect sense. Your concerns about consumption based estimates a...
Each Jaga rad has its own temp sensor and fan controller. There is no central connection to the heat pump. Same with Mitsi and just about every othe...
Not a real problem. If the rad output is correct at the design FT and design OAT, then it will also be (almost) correct at the lower FT determined...
Ah, that makes sense and the 7kW Vaillant plus backup is a strategy a neighbour of mine has, so far successfully, adopted. Note that at -2 the 7kW Va...
- 26 Forums
- 2,283 Topics
- 51.1 K Posts
- 162 Online
- 5,944 Members
Join Us!
Podcast Picks
Latest Posts
-
RE: Grant 13kW Aerona3 - issues getting zones to temp
Thanks for ckarifying. the installers seem t...
By Crimson , 2 hours ago
-
RE: Renewables & Heat Pumps in the News
Our average cost of the retrofit part of the work is ar...
By ASHP-BOBBA , 9 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@agentgeorge it has got 2, the other bleed screw is the...
By AdamK , 9 hours ago
-
-
RE: Maximising Home Automation: Integrating Octopus Energy & More
Of course, @transparent; you're right. In fact, it's a ...
By Majordennisbloodnok , 11 hours ago
-
RE: Octopus Cosy Heat Pump Owners & Discussion Thread
Hi Only joined the forum today and have found this t...
By Pwils , 12 hours ago
-
RE: Installer Fitted 9kW Instead of 11kW Heat Pump and Changed MCS Paperwork - What do I do?
@transparent Would that mean they were rubbishing your ...
By Toodles , 12 hours ago
-
I too felt the podcast was useful but think it could do...
By AndrewJ , 13 hours ago
-
@adamk apologies but did not understand what exactly yo...
By Eliuccio , 14 hours ago
-
Putting a 30 cm. radio controlled wall clock on Freegle...
By Toodles , 14 hours ago
-
RE: Who's your electricity provider and what's your tariff?
I’m with octopus, best tariff for heat pump and battery...
By AgentGeorge , 15 hours ago
-
RE: The Hidden Secret to a Successful Heat Pump: Pipe Size Matters
I assume you are referring to this postand yes indeed y...
By JamesPa , 15 hours ago
-
RE: Faulty Clivet heat pump out of the box
@steveimpey Welcome to the Homely control club! Toodles...
By Toodles , 17 hours ago
-
RE: Havenwise App Help & Forum Support – Get the Most from Your Heat Pump
@nickhorne Unfortunately not. We take the "normal" IOG ...
By HCas , 1 day ago
-
RE: Mixture of copper and plastic CH pipework. Will it be ok, or need changing?
In principle yes. Some heat pumps (I think including D...
By JamesPa , 1 day ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
Some of the circuits in my home are not protected by RC...
By Batpred , 1 day ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
Aqara sells some inexpensive hubs (usb dongle size) tha...
By Batpred , 2 days ago
-
RE: Extend the colder range of the weather compensation curve?
@thebinman In answer to this and personal...
By TechnoGeek , 2 days ago
-
RE: When to use Octopus Intelligent Go tariff with my heat pump and battery
@treewizard That's probably fine, provided as you say...
By GrahamF , 2 days ago