Unfortunately Home Assistant only stores detailed historical data for 10 days, then it saves hourly data long term. I need to tweak the system to stor...
The maximum flow temp has always been within a degree of what the WC curve has called for. Coldest day here since it was installed was between minus...
It's not that I'm chasing low flow temperatures forcthe sake of it, more a case keeping the house at a comfortable temperature in the most economical...
Looking at the ASP flow temp, it does indeed switch over to the immersion at 50 degrees. I've spoken to the installer, and they will replace the...
I think the switching is because the thermostat in the immersion heater element is switching on and off because the water close to the element is reac...
Ah, I see. I hadn't seen that option. The title's a bit misleading- "hourly" meaning "for one hour" rather than what I assumed "hour by hour" I've p...
@gary Ah, OK. I find that way of doing it more confusing, as it doesn't show the actual time on the horizontal axis. I get your point about matching...
@gary Not sure I understand what you are asking for?
Melcloud graph for the last 24 hours. I have the heating scheduled to go off at 20:00 and back on at 23:30. This is because I'm on an EV tariff with c...
Ran the Legionella cycle again overnight, with the thermostat on its highest setting. It did eventually reach 60 degrees, after 2 hours. The cycle ...
Can't the suppliers, or at least the smart meter network people, tell when local demand is straining the grid by just looking at the supply voltage at...
To be fair, the total demand for the period was a maximum of 3kW - the ASHP goes idle while the immersion is running. In contrast, my electric car's...
- 26 Forums
- 2,396 Topics
- 54.3 K Posts
- 475 Online
- 6,077 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Radiator sizing sanity check
Thanks for the update. As you say you are now piggy in...
By JamesPa , 9 minutes ago
-
RE: Recommended home battery inverters + regulatory matters - help requested
@batpred, @transparent thanks Since the i...
By JamesPa , 16 minutes ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
I hadn't spotted that there were two pumps in the UFH (...
By JamesPa , 2 hours ago
-
RE: Setback savings - fact or fiction?
Never assume it makes an ass of u and me! You need the...
By JamesPa , 2 hours ago
-
RE: New Mitsubishi Ecodan 11.2kW installation - L9 errors and maybe more
Before I answer your specific questions just one more t...
By JamesPa , 2 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
@agentgeorge Fortunately the one thing that you *won't*...
By dr_dongle , 2 hours ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
@chandykris Thank you for your detailed response.It is ...
By Wally , 3 hours ago
-
RE: Electricity price predictions
Great point, one of the key ones in my chat with Octopu...
By Batpred , 12 hours ago
-
RE: Running from backup generaor in powercut?
Definitely and professionals sometimes miss it. I had...
By Batpred , 13 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Let me point out that there are many Chinese suppliers ...
By Transparent , 17 hours ago
-
RE: Weather compensation- why you should use it
@majordennisbloodnok — The Two Ronnies Mastermind sketc...
By cathodeRay , 17 hours ago
-
Just realised that this image of the cylinder cupboard ...
By Sheriff Fatman , 21 hours ago
-
RE: Rodents! A word of warning for heat pump owners
Two thoughts: 1: Let's ask @david-s if Primary Pro in...
By Transparent , 21 hours ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
In the diagram below, I describe my understanding of th...
By Batpred , 22 hours ago
-
I need to have a look out for it. I know IBM feeds some...
By Batpred , 22 hours ago
-
-
RE: Daikin Atherma ASHP Cycling 6 Times an Hour?
Thanks for your reply. Yes that's a good idea to try a...
By John Marshall , 1 day ago
-
RE: Hot water heating in parallel with space heating
An external heat exchanger would need a pump which woul...
By bontwoody , 1 day ago
-
RE: Gen 6 Samsung ASHP losing 20C of DHW in 60 min directly after generation
@ecobaker Thanks for this. I've had it in both slots. ...
By andbeck , 2 days ago
-
RE: Air source heat pump circuit not operational
Welcome to the forums. If the thermostat shows it’s c...
By Mars , 2 days ago