Last seen: Dec 1, 2023
@mikefl @mab, if it helps at all, here's today's data on my Grant 17kW model. The defrost cycles are depicted by the cliff edge drops in the flow temp...
@shapingstuff Here's the electric consumption Vs heat generation of my Grant 17kW unit - EmonCMS link. I used a emonTX with CT clamps to measure ...
I would say you are looking for a controller like pictured in @allyfish 's post here:/p> Or the controller to the right of the picture here:/p> ...
The warmup device is usually for the mat type electric underfloor heating, commonly found in bathrooms.
On most installations the Grant controller is just used to configure the system and external controls are fitted to demand heating and hot water. ...
It is more efficient in the long run as you want the flow temperature to be as low as possible while keeping the house warm, with the heat pump runnin...
Was this a zone on the EvoHome system or just had water flowing when one of the zones was calling for heat? If you can get the heat pump running...
@sirpatchuk1980 I had EvoHome in my last house, a great (if expensive!) setup that did work on my gas boiler. I would not use it on my heat pump tho...
@robl thank you. It's definitely the complete circuit (DHW out and around to the DHW return) - exasperated by the Mixergy technology with their pump o...
Sorry for the delay, notifications for this forum go to my spam folder. The installer I used suggested fitting a motorised valve, linked to the same...
@webcmg From the pictures on your first post it appears that the DHW outlet and secondary return inlet are piped straight up into your ceiling ...
@kk_777 don't worry, I hadn't heard about thermosiphoning either until I started looking in to why the tank heat loss was so great. As for the tank ...
- 25 Forums
- 1,513 Topics
- 31.8 K Posts
- 17 Online
- 1,283 Members
Join Us!
Latest Posts
-
RE: Additional Battery v Wind Turbine v Ripple
I should add, being an investment, the value of your in...
By Old_Scientist , 4 hours ago
-
RE: Ecodan - flow rates, sensors, settings
Achieving an accurate flow measurement is probably the ...
By Derek M , 7 hours ago
-
RE: Ecodan ASHP - How to optimise my set up?
Again, thank you for another thorough post, @derek-m - ...
By rhh2348 , 9 hours ago
-
RE: Delivering a smart and secure electricity system: government consultation
@Transparent.Now that I am represented by a new MP I th...
By IanMK13 , 11 hours ago
-
RE: Vaillant aroTHERM plus not level or flat - what base is best under an external unit?
Similar thread here
By Johnmo , 12 hours ago
-
RE: VDI 2035 heating water specification
Been looking and it seems a good little project. Ever...
By Johnmo , 1 day ago
-
RE: Do I accept an ASHP and Solar Panel retrofit under the HUG 2 scheme?
Will do. I'm currently waiting for another survey / vis...
By dssr , 2 days ago
-
The company that did the borehole were expecting us to ...
By Johnmo , 2 days ago
-
-
RE: The Misquote That Ruined the Heating Industry
@abernyte manufacturer training is pretty average. They...
By Mars , 2 days ago
-
-
RE: ECO4 Scheme and EPC ratings
@mellow Thanks. Given there is a scheme requirement to ...
By Old_Scientist , 3 days ago
-
RE: Do I just go with the lowest quote for my heat pump?
@jancold To me its a no-brainer then, a max 40C flow te...
By bontwoody , 3 days ago
-
-
RE: Heat Pump Books Beginners – Bodge Buster & From Zero To Heat Pump Hero
@editor Presumably he had some good weather Compensatio...
By Toodles , 4 days ago
-
RE: New Vaillant 7kW aroTherm ASHP or oil boiler dilemma/decision??
Storage capacity really is dependent on storage tempera...
By Johnmo , 4 days ago
-
RE: HP Cycling, Expected or Undesirable
Just a little update. I ordered a longer shielded twin ...
By bontwoody , 4 days ago
-
RE: Domestic hot water timer doing crazy things on my Grant Aerona3 10kW air source heat pump
Thanks @allyfish for the pics and info. Spoke to the in...
By Mellow , 4 days ago
-
RE: Aira Heat Pump: Stylish Scandinavian Heating
It's been a busy day for calls and emails from Aira. I ...
By MikeH , 4 days ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
Hmm. A bit of a nuanced answer, methinks. As I've alr...
By Majordennisbloodnok , 4 days ago
Latest Topics
-
Ecodan - flow rates, sensors, settings
By rhh2348 10 hours ago
-
Replacing mains water with well water
By Johnmo 2 days ago
-
Additional Battery v Wind Turbine v Ripple
By bontwoody 2 days ago
-
By jamespipe 3 days ago
-
VDI 2035 heating water specification
By Johnmo 3 days ago
-
Do I just go with the lowest quote for my heat pump?
By Jancold 5 days ago
-
The Misquote That Ruined the Heating Industry
By Alec Morrow 5 days ago
-
Battery Storage Wiring Gauge Question
By Puff 6 days ago
Members Online
No online members at the moment