Joining the Renewable Heating Hub forums is completely free and only takes a minute. By registering you’ll be able to ask questions, join discussions, follow topics you’re interested in, bookmark useful threads and receive notifications when someone replies. Non-registered members also do not have access to our AI features. When choosing your username, please note that it cannot be changed later, so we recommend avoiding brand or product names. Before registering, please take a moment to read the Forum Rules & Terms of Use so we can keep the community helpful, respectful and informative for everyone. Thanks for joining!
Last seen: Dec 1, 2023
@mikefl @mab, if it helps at all, here's today's data on my Grant 17kW model. The defrost cycles are depicted by the cliff edge drops in the flow temp...
@shapingstuff Here's the electric consumption Vs heat generation of my Grant 17kW unit - EmonCMS link. I used a emonTX with CT clamps to measure ...
I would say you are looking for a controller like pictured in @allyfish 's post here:/p> Or the controller to the right of the picture here:/p> ...
The warmup device is usually for the mat type electric underfloor heating, commonly found in bathrooms.
On most installations the Grant controller is just used to configure the system and external controls are fitted to demand heating and hot water. ...
It is more efficient in the long run as you want the flow temperature to be as low as possible while keeping the house warm, with the heat pump runnin...
Was this a zone on the EvoHome system or just had water flowing when one of the zones was calling for heat? If you can get the heat pump running...
@sirpatchuk1980 I had EvoHome in my last house, a great (if expensive!) setup that did work on my gas boiler. I would not use it on my heat pump tho...
@robl thank you. It's definitely the complete circuit (DHW out and around to the DHW return) - exasperated by the Mixergy technology with their pump o...
Sorry for the delay, notifications for this forum go to my spam folder. The installer I used suggested fitting a motorised valve, linked to the same...
@webcmg From the pictures on your first post it appears that the DHW outlet and secondary return inlet are piped straight up into your ceiling ...
@kk_777 don't worry, I hadn't heard about thermosiphoning either until I started looking in to why the tank heat loss was so great. As for the tank ...
- 26 Forums
- 2,726 Topics
- 63.9 K Posts
- 789 Online
- 7,131 Members
Join Us!
Installer Finder
Degrees of Separation
Latest Posts
-
RE: Indevolt Batteries UK Support & Info Thread
Indeed. I guess the questions are, who is responsible...
By JamesPa , 49 minutes ago
-
@trebor12345 If you select the Change Rate Plan button,...
By Toodles , 2 hours ago
-
@grahamh-energy-donkey — thanks for the clarifications....
By cathodeRay , 7 hours ago
-
RE: HeatGeek vs Octopus surveys: puzzling disparity - any ideas why?
A good analysis with which I agree
By JamesPa , 22 hours ago
-
RE: Jokes and fun posts about heat pumps and renewables
@majordennisbloodnok Well, I can use such terms as HMRC...
By Toodles , 23 hours ago
-
RE: Heat Pump Servicing & Maintenance – Good Value or Rip-Off?
I'd picked up that there was a leak coming from around ...
By Sheriff Fatman , 1 day ago
-
RE: Who's your electricity provider and what's your tariff?
Great info. Thank you. Regards Pete
By peterackstraw , 1 day ago
-
-
RE: Microgeneration Certification Scheme (MCS)
@jamespa A cynical view but, I fear that it is a fair ...
By Toodles , 2 days ago
-
RE: Samsung heat pump - data cable issue
That's well done. Cable is the correct type (LIYCY = 2x...
By bobflux , 4 days ago
-
RE: Electricity price predictions
I agree, we will find out at the next budget whether th...
By Old_Scientist , 5 days ago
-
RE: Missing flow temperature in Heat Geek proposal
@editor I went through HG website, so should be ok for ...
By sttpd1917 , 5 days ago
-
RE: Air to air bus grant installer anywhere
The through wall two hole ones have their place (listed...
By EtchedPixels , 5 days ago
-
I hope it goes ok, Hon can be hard to set up IF the sof...
By Graham Hendra , 5 days ago