@jwilliams89 We're quite satisfied with the performance we get from expanded and haven't seen any reason to tweak things further. It's settled on a HC...
@colin All I'm doing to monitor COP is taking daily readings from the sensoCOMFORT for power consumed and environmental yield, then doing the maths ...
Hi folks, Here are some charts showing how things have progressed since the end of November (the data immediately after my mid-November commissionin...
Hi @derek-m I didn't know that about the cold weather leading to hotter radiators; now that you say it, that makes sense. Our controller is wire...
I have another question, this time about TRVs. I've seen many of the more technically minded posters saying that the TRVs should be left fully open, a...
I didn't wait til the end of the week and switched over to expanded mode + adaptive heat curve last Tuesday. I'm not wholly sure what to make of the d...
Thanks both, I appreciate your input. I think I'm going to leave things as I have them til the end of the week, for data collection, and then try swit...
I agree about the adaptive heat curve using the expanded room temp, and that's what I'm working toward. Since the manual asks that the suitable heat c...
Hi @jaspera -- thanks for that info. It looks like we have different controllers (I have a VRC720F) and in the manual Vaillant have removed the text y...
@derek-m Thanks very much -- I think I understand this now, as well as the source of my confusion. My Vaillant 12kW operates only w/the Vaillant Sen...
@derek-m, I have a question about this statement. I think I understand your later explanation of how premature shutoff happens (link) but I don't unde...
- 26 Forums
- 2,396 Topics
- 54.3 K Posts
- 253 Online
- 6,077 Members
Join Us!
Worth Watching
Latest Posts
-
RE: Recommended home battery inverters + regulatory matters - help requested
yes, the circuit needs the usual protection, mcb and ma...
By Batpred , 2 hours ago
-
RE: Help me keep the faith with my air source heat pump installation
I agree and that’s why I don’t believe a lot o...
By SimonF , 4 hours ago
-
RE: ASHP Energy Consumption: Aira 12kW heat pump
I doubt that matters, ToU tariffs are for the benefit o...
By JamesPa , 5 hours ago
-
RE: Free Ecoheat Heat Pump Install
@deltona Yes older houses are problematic like that, bu...
By bontwoody , 7 hours ago
-
RE: Radiator sizing sanity check
As I mentioned early on the cost of supplying and fitti...
By JamesPa , 10 hours ago
-
RE: Advice for a novice on Mitsubishi Ecodan 6kW
I hadn't spotted that there were two pumps in the UFH (...
By JamesPa , 12 hours ago
-
RE: Setback savings - fact or fiction?
Never assume it makes an ass of u and me! You need the...
By JamesPa , 12 hours ago
-
RE: New Mitsubishi Ecodan 11.2kW installation - L9 errors and maybe more
Before I answer your specific questions just one more t...
By JamesPa , 12 hours ago
-
RE: Electricity price predictions
Great point, one of the key ones in my chat with Octopu...
By Batpred , 23 hours ago
-
RE: Running from backup generaor in powercut?
Definitely and professionals sometimes miss it. I had...
By Batpred , 23 hours ago
-
RE: New Fogstar 15.5kWh upright solution
Let me point out that there are many Chinese suppliers ...
By Transparent , 1 day ago
-
RE: Weather compensation- why you should use it
@majordennisbloodnok — The Two Ronnies Mastermind sketc...
By cathodeRay , 1 day ago
-
Just realised that this image of the cylinder cupboard ...
By Sheriff Fatman , 1 day ago
-
RE: Rodents! A word of warning for heat pump owners
Two thoughts: 1: Let's ask @david-s if Primary Pro in...
By Transparent , 1 day ago
-
RE: Solis S6-EH1P8K-L-PLUS – Why I Chose It and What I’ve Learned So Far
In the diagram below, I describe my understanding of th...
By Batpred , 1 day ago
-
I need to have a look out for it. I know IBM feeds some...
By Batpred , 1 day ago
-
-
RE: Daikin Atherma ASHP Cycling 6 Times an Hour?
Thanks for your reply. Yes that's a good idea to try a...
By John Marshall , 2 days ago
-
RE: Hot water heating in parallel with space heating
An external heat exchanger would need a pump which woul...
By bontwoody , 2 days ago
-
RE: Gen 6 Samsung ASHP losing 20C of DHW in 60 min directly after generation
@ecobaker Thanks for this. I've had it in both slots. ...
By andbeck , 2 days ago