@jwilliams89 We're quite satisfied with the performance we get from expanded and haven't seen any reason to tweak things further. It's settled on a HC...
@colin All I'm doing to monitor COP is taking daily readings from the sensoCOMFORT for power consumed and environmental yield, then doing the maths ...
Hi folks, Here are some charts showing how things have progressed since the end of November (the data immediately after my mid-November commissionin...
Hi @derek-m I didn't know that about the cold weather leading to hotter radiators; now that you say it, that makes sense. Our controller is wire...
I have another question, this time about TRVs. I've seen many of the more technically minded posters saying that the TRVs should be left fully open, a...
I didn't wait til the end of the week and switched over to expanded mode + adaptive heat curve last Tuesday. I'm not wholly sure what to make of the d...
Thanks both, I appreciate your input. I think I'm going to leave things as I have them til the end of the week, for data collection, and then try swit...
I agree about the adaptive heat curve using the expanded room temp, and that's what I'm working toward. Since the manual asks that the suitable heat c...
Hi @jaspera -- thanks for that info. It looks like we have different controllers (I have a VRC720F) and in the manual Vaillant have removed the text y...
@derek-m Thanks very much -- I think I understand this now, as well as the source of my confusion. My Vaillant 12kW operates only w/the Vaillant Sen...
@derek-m, I have a question about this statement. I think I understand your later explanation of how premature shutoff happens (link) but I don't unde...
- 21 Forums
- 1,962 Topics
- 42.6 K Posts
- 67 Online
- 2,275 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Setback savings - fact or fiction?
And here in case any one wants it is the code I used in...
By cathodeRay , 54 seconds ago
-
RE: What is the best strategy for operating a very oversized heat pump?
@jamespa Samsung has it 'Quiet mode' and I use it a ...
By IRMartini , 4 minutes ago
-
RE: Newbie out of her depth – Samsung AE120RXYDEG 12kW heat pump
No need for apologies, just cautioning about getting to...
By JamesPa , 18 minutes ago
-
RE: Samsung Gen 7 R290 12kW is not behaving how I expected
Definitely its in the 20xx FSVs. Conversely it may be...
By JamesPa , 20 minutes ago
-
RE: Towel rails. An unexpected final hurdle
We have both Normal Rad for heating the room and then a...
By IRMartini , 2 hours ago
-
RE: Heat Pump Sizing & Installation Costs
Perhaps useful to have installed date too? To get conte...
By Tim441 , 4 hours ago
-
RE: SolarPV tables / online calculator
I'd be interested what others find whilst using that we...
By Majordennisbloodnok , 6 hours ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
The debate over buffer tanks in heat pump systems has b...
By Mars , 7 hours ago
-
RE: F.788 Building circuit pump reports internal fault - Vaillant Arotherm
Guess I have to wait for engineer visit. I really hope ...
By jeegnesh , 18 hours ago
-
RE: Act now to defer the UK road tax increase on EVs
@majordennisbloodnok Damn right sir. my attempt at iron...
By Jancold , 21 hours ago
-
RE: ASHP and heating issues in new build house
That’s good gives you more capacity. It made me think, ...
By Terry1812 , 22 hours ago
-
RE: Seewet manhole cover within r290 exclusion zone
Thanks! I asked Vaillant, and they say I should be fi...
By dbrb2 , 1 day ago
-
Looking for the Grant Aerona 3 setting to turn off completely at 20 OAT
I'm running my Aerona 3 on WC and the 'warm end of that...
By damonc , 1 day ago
-
RE: Do I just go with the lowest quote for my heat pump?
So after signing in Sept in two weeks the install may s...
By Jancold , 1 day ago
-
RE: Victorian Semi Retrofit / Extension ASHP and UFH Advice
When you are renovating is always a good time, as it ma...
By JamesPa , 1 day ago
-
RE: Just one room not reaching desired temperature
Looks like this issue is now resolved. Aira installed a...
By ChandyKris , 1 day ago
-
There have been several people on the OpenEnergyMonitor...
By RobS , 2 days ago
-
RE: Say hello and introduce yourself
Good point @jamespa But that probably strengthens @ch...
By Transparent , 2 days ago
-
RE: Visit a Heat Pump sessions.
Congratulations @toodles, that's a fantastic result. We...
By Old_Scientist , 2 days ago
Latest Topics
-
Heat Pump Sizing & Installation Costs
By Mars 6 hours ago
-
Volumisers in Heat Pump Systems: Does Placement Matter?
By Mars 7 hours ago
-
SolarPV tables / online calculator
By MichelleC 14 hours ago
-
By Toodles 2 days ago