Reply
RE: ASHP sizing - value of Heat Transfer Coefficient

@bontwoody If retrofitting an ASHP after the brood have flown the nest, would it not be sensible to take into account the next property owner's likely...

3 days ago
Reply
RE: Incorrect Billing of Customers with a Smart Meter

I can be quite 'anal' at checking my bills. With energy bills, it used to be very straightforward: read the electricity meter for kWh used since the ...

5 days ago
Reply
RE: Installing your own ASHP - DIY

@tomasmcguinness Have you been able to perform any sanity check on that figure? I'm thinking of the 'divide annual gas consumption by 2900' rule of t...

3 weeks ago
Reply
RE: Microbore Central Heating Plumbing, will it be a barrier / pain?

@mattc All the existing (designed for T50) radiators are single panel, only around half with fins. I think the system was probably well designed when ...

3 weeks ago
Reply
RE: Microbore Central Heating Plumbing, will it be a barrier / pain?

I have 10mm copper microbore installed behind dot & dab plasterboard for the downstairs radiators. I’ve done my heat loss survey and have conclude...

3 weeks ago
Reply
RE: Aira Heat Pump: Stylish Scandinavian Heating

That's why I didn't go for a Tado controller for my boiler control 7 or 8 years ago. Instead, I went with a Drayton miGenie internet-enabled controll...

3 weeks ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

@derek-m - The electricity supply industry relies on 'diversity' with regard to phase balancing and hopes for a reasonable balance of loads across t...

4 weeks ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

Here is NGED's policy document: NGED Standardisation of Fusing to 80A My 100A service head was replaced with an 80A one last year after I rashly rep...

4 weeks ago
Reply
RE: EV charger installation question – I don't want to bury the cable

@transparent If it's a Podpoint Solo EV charger, a quick look at the installation guide suggests it has has a form of PEN fault detection and can be...

4 weeks ago
Reply
RE: Delivering a smart and secure electricity system: government consultation

At present, the focus of many people - I'm thinking of PV and domestic battery owners here - is on export limitation to the grid. (Call me a cynic, b...

4 weeks ago
Reply
RE: EV charger installation question – I don't want to bury the cable

@hem Depending on the charger you install, an option may be to use an SWA cable with an integral cat5 cable. This may be used either for an intern...

4 weeks ago