We have some towel rail radiators which are connected directly to the HP flow/return and mixing valves ar the underfloor manifolds - I would expect th...
I use one of these with the device in a fused-spur surface-mounted box next to the consumer unit, and the sensor clamp around the live to the pump in ...
It would be useful to see the real-time energy going into the pump from a Watt meter, it might show something. I attach one of mine below, mine also c...
For my system, the issue with a setback isn't so much the LWT, it's the delta between the LWT and RWT: the compressor runs a lot harder in the warmup ...
@tfb8 If the Winda is still sending control signals, then the relay setting for the Wunda zones must still be set in the Wundasmart app; You can remov...
If I'm understanding you right, are you saying you just want to control the system off one thermostat? If so, you can do this using the WundaSmart app...
@kev-m Yes, it's in heating mode. For reasons I still don't understand the HP can spin up to do a DHW cycle when the tank temp is very close to setpoi...
Following some of John Cantor's videos explains why cycling gently (2-3 times/hr) is actually just creating an average lower flow temp. Our pump cut...
Mitsubishi provided the flow chart below, after quite a lot of back-and-forth trying to explain the high flow temps and power spikes.
We're at over 6 some days, with low flow temps between 23 and 25 - happy days!
Rod Forum Handle: Rod Manufacturer: Mitsubishi Model: Ecodan 11.2KW Type: ASHP Arrangement: Mono Area of Country: Kent Home Type: B...
- 21 Forums
- 1,983 Topics
- 43.2 K Posts
- 37 Online
- 2,309 Members
Join Us!
Heat Pump Dramas?
Thinking about installing a heat pump but unsure where to start? Already have one but it’s not performing as expected? Or are you locked in a frustrating dispute with an installer or manufacturer? We’re here to help.
✅ Pre-Installation Planning
✅ Post-Installation Troubleshooting
✅ Performance Optimisation
✅ Complaint Support (Manufacturer & Installer)
Latest Posts
-
RE: Confused about Samsung Gen6 Hot Water Controller
Found a copy on this really good website 🤣 ...
By DerekDeLeon , 4 minutes ago
-
RE: Smart TRV experiences (ideally integrating with Midea heat pump)
@madbilly - I think you may risk over-complicating this...
By cathodeRay , 33 minutes ago
-
RE: Volumisers in Heat Pump Systems: Does Placement Matter?
@sunandair I can't get my system higher than 35 or 3...
By davidnolan22 , 2 hours ago
-
RE: Nibe F2040 ASHP PCB failure
@delta I’ve raised this with NIBE today. Their team is ...
By Mars , 11 hours ago
-
RE: Are MCS are finally improving (some of) their guidelines?
Encouragement of installers to take account of the emit...
By JohnR , 11 hours ago
-
In our case the pipe run for the heat pump is short and...
By madbilly , 11 hours ago
-
Plug and play solar. Thoughts?
What do you think of these plug-and-play Balcony Solar...
By Lucia , 14 hours ago
-
@toodles no, unfortunately we don’t have access to the ...
By Simon and Zoe , 14 hours ago
-
RE: The EPC Dilemma: How Current Ratings Fail Heat Pumps
Hi, im not an expert on EPCs but today got a D for my 1...
By rodwebster , 15 hours ago
-
@sandman1600 What I mean is, your UFH power is 79wm2...
By davidnolan22 , 15 hours ago
-
RE: Vaillant AroTherm Plus 7kW
Thank you James for such a complete write up. We also h...
By Judith , 16 hours ago
-
RE: Ecodan Auto Adapt Questions
It wasnt me that mentioned this, was someone else, I wa...
By JamesPa , 16 hours ago
-
RE: Renewables & Heat Pumps in the News
In a move that potentially promises to benefit homeowne...
By Mars , 16 hours ago
-
RE: Vaillant water pressure gauge vs Analogue gauge
I have the same, so equally interested in the answer. ...
By JamesPa , 16 hours ago
-
RE: Thinking of ripping our my IVT Greenline HT Plus C model and replacing with a gas boiler.
Somebody has to pay for their ignorance! In fairness ...
By JamesPa , 21 hours ago
-
Thats simply not true (to any material extent), which i...
By JamesPa , 1 day ago
-
Database of heat pump performance data?
Hi all, I really like Heatpunk, especially the way th...
By madbilly , 1 day ago
-
RE: Air source heat pump roll call
Good idea 🙂 Manufacturer: MideaModel:10kW R32 Monob...
By madbilly , 1 day ago
-
RE: What is the best approach for primaries in heat pump installations?
Don't forget there is no such thing as zero loss insula...
By Judith , 2 days ago
-
RE: Battery storage to run Heat Pump.
@transparent Flexibility Services are different to w...
By Lucia , 2 days ago
Latest Topics
-
Plug and play solar. Thoughts?
By Lucia 14 hours ago
-
By JamesPa 17 hours ago
-
Vaillant water pressure gauge vs Analogue gauge
By jeegnesh 18 hours ago
-
Database of heat pump performance data?
By madbilly 1 day ago
-
By madbilly 1 day ago
-
Confused about Samsung Gen6 Hot Water Controller
By ntruby 2 days ago
-
help with new bathroom and towel radiator
By AdamK 3 days ago
-
Grant Aerona fine tuning advice needed
By Stopbar 3 days ago